Страница 1: ... or specified parts for the installation work The use of defective parts could cause an injury or leakage of water due to a fire an electric shock the unit falling etc When plugging the power supply plug into the outlet make sure that there is no dust clogging or loose parts in both the outlet and the plug Make sure that the power supply plug is pushed completely into the outlet If there is dust c...

Страница 2: ...uch machine oil Salty places such as the seaside Where sulfide gas is generated such as a hot spring Where there is high frequency or wireless equipment 1 3 SPECiFiCATiONS 1 3 1 POWER SUPPLY AND INDOOR OUTDOOR WIRE CONNECTION Power should be taken from an exclusive branched circuit Wiring work should be based on applicable technical standards Wiring connections should be made following the diagram...

Страница 3: ...it _Seal the wall hole Wall hole Vf_ sl C _FL I Fix the pip etO _ A_I wall with pipe fixing I Lband E j Cut off the Pipe fixing band extra length _ Fixing screw F r the leak test apply insulating mate rial tightly so that there is no gap J 6 4 3 When the piping is to be attached to a wall containing metals tin plated or metal netting use a chemically treated wooden iece 25 32 in 20 mm or thicker b...

Страница 4: ... and no external force is conveyed to the connecting section of the terminal block 7 Firmly tighten the terminal screws to prevent them from loosening After tightening pull the wires lightly to confirm that they do not move 8 Secure indoor outdoor unit connecting wire A and the ground wire with conduit cover Never fail to hook the claw of the conduit cover to the electrical box Attach the conduit ...

Страница 5: ...p hook it onto the back rib and use it as a spacer to lift the indoor unit Fig 5 8 Connect the refrigerant piping with the extension pipe B 9 Thrust the lower part of the indoor unit into the installation plate 1 cap Fig 1 _n cap Fig 3 J Fig 5 Fig 2 _ Drain hose Fig 4 Rear or downward piping 1 Put the refrigerant piping and the drain hose together then firmly apply piping tape G from the end 2 Ins...

Страница 6: ...lock More than 1 12 32 in 35 mm 1 For future servicing give extra length to 1 the connecting wires Power supply cord K hdoor outdoor unit connecting wire A 3 2 FLARING WORK 1 Cut the copper pipe correctly with pipe cutter Fig 1 2 2 Completely remove all burrs from the cut cross section of pipe Fig 3 Put the end of the copper pipe to downward direction as you remove burrs in order to avoid to let b...

Страница 7: ...ctions for details Press the E O SW Test run will be performed for 30 minutes If the left side lamp of the operation indicator blinks every 0 5 seconds inspect the indoor outdoor Emergency operation switch unit connecting wire A for mis wiring After the test run E O SW emergency COOL mode 75 F 24 C COOL will start 3 To stop operation press the E O SW several times until all LED lamps turn off Refe...

Страница 8: ...g of the air conditioner pump down the system following the procedure below so that no refrigerant is released into the atmosphere 1 Connect the gauge manifold valve to the service port of the stop valve on the gas pipe side of the outdoor unit 2 Fully close the stop valve on the liquid pipe side of the outdoor unit 3 Close the stop valve on the gas pipe side of the outdoor unit almost completely ...