26
3 SIGNALS AND WIRING
3.1 Connection example of power circuit
Using servo amplifier with DC power supply input
Connection example
Refer to the following for the signals and wiring not described in this section.
■
MR-J5-10_ to MR-J5-100_/MR-J5W2-22G/MR-J5W2-44G/MR-J5W3-222G
*1 For the power supply specifications, refer to "Servo amplifier standard specifications" in the following user's manuals.
MR-J5-G/MR-J5W-G User's Manual (Introduction)
MR-J5-A User's Manual (Introduction)
*2 Use a magnetic contactor with an operation delay time (interval between current being applied to the coil until closure of contacts) of 80
ms or less. Bus voltage may drop depending on the main circuit voltage and operation pattern, causing a dynamic brake deceleration
during a forced stop deceleration. If dynamic brake deceleration is not required, delay the time to turn off the magnetic contactor.
*3 Operating the on switch and off switch with the DC power supply meets IEC/EN 60204-1 requirements.
*4 Do not share the 24 V DC power supply for interface with a magnetic contactor. Always use the power supply designed exclusively for
the magnetic contactor.
*5 If wires used for L11 and L21 are thinner than wires used for L1 and L3, use a fuse.
Page 170 When using the servo amplifier with the DC power supply input
■
MR-J5-200_/MR-J5-350_/MR-J5W2-77G/MR-J5W2-1010G/MR-J5W3-444G
MC
*2
L1
L2
L3
L11
L21
MC
MC
MCCB
SK
*5
+
-
*1
RA1
Emergency stop switch
AC/DC
24 V DC
*3*4
200 V AC to
240 V AC
(283 V DC to
340 V DC)
Servo amplifier
3-phase or 1-phase
Malfunction
OFF
ON
converter
MC
*2
L1
L2
L3
L11
L21
MC
MC
MCCB
SK
*5
+
-
*1
RA1
N-
AC/DC
24 V DC
*3*4
200 V AC to
240 V AC
(283 V DC to
340 V DC)
Servo amplifier
3-phase or 1-phase
Malfunction
OFF
ON
Emergency stop switch
converter
Содержание MR-J5 Series
Страница 1: ...MR J5 User s Manual Hardware MR J5 _G_ MR J5W_ _G MR J5 _A_ Mitsubishi Electric AC Servo System ...
Страница 2: ......
Страница 315: ......