6 OPTIONS AND PERIPHERAL EQUIPMENT
6.2 Regenerative option
6.2
Regenerative option
Combination and regenerative power
The power values in the table are resistor-generated powers and not rated powers.
200 V class
*1 Install a cooling fan when using this.
*2 Depending on the operating conditions, a cooling fan must be installed.
Page 144 Connection of regenerative option
Servo amplifier
Regenerative power [W]
Built-in
regenerative
resistor
MR-
RB032
[40 Ω]
MR-RB12
[40 Ω]
MR-RB14
[26 Ω]
MR-RB30
[13 Ω]
MR-RB3N
[9 Ω]
MR-RB34
[26 Ω]
MR-RB50
[13 Ω]
MR-RB5N
[9 Ω]
MR-J5-10_
30
MR-J5-20_
10
30
100
MR-J5-40_
10
30
100
MR-J5-60_
10
20
100
MR-J5-70_
30
100
300
MR-J5-100_
30
100
300
MR-J5-200_
100
300
500
MR-J5-350_
100
300
500
MR-J5W2-22G
20
100
MR-J5W2-44G
20
100
MR-J5W2-77G
100
300
MR-J5W2-1010G
100
300
MR-J5W3-222G
30
100
300
MR-J5W3-444G
30
100
300