6 OPTIONS AND PERIPHERAL EQUIPMENT
6.1 Cable/connector sets
135
6
MR-D05UDL3M-B STO cable
This cable is for connecting an external device to the CN8 connector.
Configuration diagram
Internal wiring diagram
*1 Do not use the two core wires with orange insulators (with red or black dots).
Ethernet cable
For the wiring of CC-Link IE TSN, use a cable that meets the following standards.
A commercially available product example is as follows. For the latest product information, contact the manufacturer.
*1 The SC-E5EW cable is for in-cabinet and indoor uses. The SC-E5EW-L cable is for outdoor use.
For cables other than SC-E5EW(-L), refer to the CC-Link Partner Association website (https://www.cc-link.org/en/).
Precautions
• When branching the CC-Link IE TSN network using a switching hub, use a switching hub (Class B) that is recommended by
the CC-Link Partner Association. Although a switching hub (Class A) can also be used, there are restrictions on the type of
topology that can be used. For details, refer to the motion product manual.
Cable model
Cable length
Application
MR-D05UDL3M-B
3 m
Connection cable for the CN8 connector
Item
Description
Cable type
Category 5e or higher, (double shielded/STP) straight cable
Standard
One of the following standards must be met.
• IEEE802.3 1000BASE-T
• ANSI/TIA/EIA-568-B (Category 5e)
Connector
RJ-45 shielded connector
Model
Manufacturer
Contact
SC-E5EW(-L)
Mitsubishi Electric System & Service Co.,
Ltd.
Please consult your local Mitsubishi Electric representative.
CN8
MR-D05UDL3M-B
1
2
3
6
7
STO2
TOFB1
TOFB2
STO1
TOFCOM
8
4
5
STOCOM
*1
2
1
6
4
8
3
5
7
CN8 connector
Yellow (dots: black)
Yellow (dots: red)
Gray (dots: black)
Viewed from the connection part.
Gray (dots: red)
White (dots: black)
White (dots: red)
Plate
Shield