1 SERVO PARAMETER DETAILS
1.5 I/O setting servo parameters group ([Pr. PD_ _ ])
109
1
[Pr. PD51_Input device selection 3-2 (*DI3W2)]
Select the device to be assigned to the input signal of the CN3-15 pin of the MR-J5W2-_G_ or the CN3-11 pin of the MR-
J5D2-_G_.
This servo parameter is enabled only for the MR-J5W2-_G_ and MR-J5D2-_G_. The setting value is disabled for other servo
amplifiers.
[Pr. PD51.0-1_Device selection 3-2]
Refer to the following table for the setting value to be assigned to the CN3-15 pin of the MR-J5W2-_G_ or the CN3-11 pin of
the MR-J5D2-_G_.
[Pr. PD51.4_Input axis selection 3-2]
For the MR-J5W2-G_, set which axis will use the input device that was assigned in [Pr. PD05.0-1 Device selection].
When this servo parameter is "0h", the A-axis is automatically set to be enabled.
When A-axis selection is enabled, the device name is _ _ _-A. (Example: TPR1-A)
When B-axis selection is enabled, the device name is _ _ _-B. (Example: TPR1-B)
When multiple axes are enabled with this servo parameter, the input device signal is enabled for multiple axes simultaneously.
In the following cases, [AL. 037 Parameter error] occurs.
• When other than "0h" is set for a 1-axis servo amplifier
• When duplicated input devices exist
Page 109 Example of duplicated settings
■
Example of duplicated settings
When TPR1-B is duplicated, such as when for the A axis, [Pr. PD05.4] = "3h" (A and B axes enabled) and [Pr. PD05.0] =
"2Ch" (TPR1); and for the B axis, [Pr. PD05.4] = "0h" (automatic setting: B axis enabled) and [Pr. PD05.0] = "2Ch" (TPR1)
Initial value
Setting range
Setting method
Ver.
00000062h
Refer to the relevant detail No.
Common
Refer to the relevant detail No.
Model
Shaft
Connector pin No.
Initially assigned device
MR-J5W2-G_
A-axis
CN3-15
TPR3-A
B-axis
MR-J5D2-_G_
A-axis
CN3-11
B-axis
Initial value
Setting range
Ver.
62h
Refer to the text
A5
Setting
Input signal device
2C
TPR1
2D
TPR2
62
No assigned function
63
TPR3
Initial value
Setting range
Ver.
0h
Refer to the text
A5
Servo parameter number
Setting digit (BIN)
Setting details
[Pr. PD51.4]
_ _ _ x
A-axis selection
0: Disabled
1: Enabled
_ _ x _
B-axis selection
0: Disabled
1: Enabled