1 SERVO PARAMETER DETAILS
1.5 I/O setting servo parameters group ([Pr. PD_ _ ])
81
1
[Pr. PD13_Function selection D-2 (*DOP2)]
[Pr. PD13.2_INP output signal ON condition selection]
Select a condition for outputting INP (In-position).
INP (In-position) immediately after servo-on or after forced stop is canceled is off.
If no command is entered within approximately 1 ms, the servo amplifier considers command output to have been completed.
0: Within the in-position range
1: Within the in-position range and at the completion of command output
[Pr. PD14_Function selection D-3 (*DOP3)]
[Pr. PD14.1_Output device status at warning occurrence]
Select ALM (Malfunction) output status at warning occurrence.
Initial value
Setting range
Setting method
Ver.
00000000h
Refer to the relevant detail No.
Each axis
Refer to the relevant detail No.
Initial value
Setting range
Ver.
0h
Refer to the text
C4
Initial value
Setting range
Setting method
Ver.
00000000h
Refer to the relevant detail No.
Each axis
Refer to the relevant detail No.
Initial value
Setting range
Ver.
0h
Refer to the text
C4
Setting value
Device status
0
1
OFF
ON
OFF
ON
WNG
ALM
Warning occurrence
OFF
ON
OFF
ON
WNG
ALM
Warning occurrence