8
1 FUNCTIONS AND CONFIGURATION
1.3 Standard specifications
1.3
Standard specifications
200 V class
*1 This value is applicable when all I/O signals are used. Reducing the number of I/O points decreases the current capacity.
*2 This does not apply to the terminal block.
*3 Refer to the following for restrictions on using this product at an altitude exceeding 1000 m and up to 2000 m.
Page 15 Restrictions when using this product at an altitude exceeding 1000 m and up to 2000 m
Model MR-CV_
11K
18K
30K
37K
45K
55K
Output
Rated voltage
270 V DC to 324 V DC
Rated current [A]
41
76
144
164
198
238
Main circuit power
supply input
Voltage/Frequency
3-phase 200 V AC to 240 V AC, 50 Hz/60 Hz
Rated current [A]
35
65
107
121
148
200
Permissible voltage fluctuation
3-phase 170 V AC to 264 V AC
Permissible frequency fluctuation
Within ±3 %
Power supply capacity [kVA]
Page 67 Power supply capacity and generated loss
Inrush current [A]
Page 69 Inrush currents at power-on of main circuit and control circuit
Control circuit power
supply input
Voltage/Frequency
1-phase 200 V AC to 240 V AC, 50 Hz/60 Hz
Rated current [A]
0.2
Permissible voltage fluctuation
1-phase 170 V AC to 264 V AC
Permissible frequency fluctuation
Within ±3 %
Power consumption [W]
30
Inrush current [A]
Page 69 Inrush currents at power-on of main circuit and control circuit
Interface power
supply
Voltage
24 V DC ±10 %
Current capacity [A]
0.35
Capacity [kW]
11
18
30
37
45
55
Protective functions
Undervoltage protection, regenerative error protection, regenerative overvoltage shut-off, MC
drive circuit error protection, open-phase detection, inrush current suppression circuit error
protection, main circuit device overheat error protection, cooling fan error protection, overload
shut-off (electronic thermal)
Main circuit method
Converter with power regeneration function
Continuous rating [kW]
7.5
11
20
22
22
37
Instantaneous maximum rating [kW]
39
60
92
101
125
175
Satisfied standards
CE marking
LVD: EN 61800-5-1
EMC: EN 61800-3
MD: EN ISO 13849-1, EN 61800-5-2, EN 62061
UL standard
UL 508C
Structure (IP rating)
Force cooling, open (IP20)
Environment
Ambient temperature
Operation
0
˚
C to 55
˚
C (non-freezing)
Storage
-20
˚
C to 65
˚
C (non-freezing)
Ambient humidity
Operation
5 %RH to 90 %RH (non-condensing)
Storage
Ambience
Indoors (no direct sunlight); no corrosive gas, inflammable gas, oil mist or dust
Altitude
Altitude 2000 m or less
Vibration resistance
5.9 m/s
2
, 10 Hz to 55 Hz (in each of the X, Y, and Z directions)
Mass [kg]
6.1
12.1
25.0