background image

15

E

Oper

ating

Using Child Lock

 

Press

 

for 3 

seconds or 

more.

 

z

The child lock indicator is displayed.

(Example)

 

If you lock the unit when the 

POWER is OFF.

The unit will not turn on, even if you 

press the POWER switch to turn it 

on. The LCD backlight and child lock 

indicator will blink.

 

If you lock the unit when the 

POWER is ON.

The unit will not turn off, even if you 

press the POWER switch to turn it off.

Only the child lock indicator will blink.

Inf

or

mation

 

z

When the child lock is set, only the CHILD 

LOCK switch can be used. When the child 

lock is activated, other switches are not 

operable. Deactivate the child lock to use the 

other switches.

 

z

The child lock is cancelled when the power 

cord is unplugged.

 

<Releasing the child lock>

 

Press 

 for 3 seconds or 

more.

 

z

The child lock indicator goes out.

(Example)

Cleaning the Air 

(AIR PURIFIER)

2

1

1

 

Press

 

  

2

 

Press 

 

 

z

AIR PURIFIER lamp lights.

To return to the previous mode, press the AIR 

PURIFIER switch again.

Blip

Blip

The switches can be locked.

To prevent children from operating this unit, use this 

function.

To operate the air purifier only.

z

z

AIR PURIFIER

The unit cleans the air by passing it through the pre-fi lter 
and PM2.5 fi lter. The dehumidifi er function is disabled. 

Inf

or

mation

 

z

The air passes through the PM2.5 fi lter in all modes, 

cleaning the air even if the AIR PURIFIER lamp is not lit.

 

z

Cigarette smoke and toxins found in smoke, such as 

carbon monoxide, cannot be removed with these fi lters.

PM2.5 fi lter for replacement

 

˜

Type: MJPR-EHPFT-HK

Contact the Mitsubishi Electric Service 

Centre for purchase. 

P24

Par

ts sold separ

atel

y

Replacement 

Parts

The PM2.5 filter is a consumable part.

Please replace the filter regularly.

Replacing PM2.5 fi lter

The PM2.5 fi lter is a consumable part.

If the filter is dirty, replace it with a new one. (The 

filter cannot be reused even if it is washed)

Conditions to replace

The PM2.5 filter has turned yellow or black due to 

cigarette smoke or dust.

The lifetime of the PM2.5 filter is one year. (It varies 

depending on the usage conditions)

Remove the pre-fi lter and replace the PM2.5 fi lter.

 

Removing the fi lter

 

P9

e01_mj_e160hr_h_cs55.indd   15

2020/07/27   15:39:22

Содержание MJ-E160HR-H

Страница 1: ...ehumidifying 12 EASY AUTO HIGH LOW MILDEW GUARD z z Cleaning the Air AIR PURIFIER 15 z z Replacement Parts 15 z z Using Child Lock 15 z z Using Louvre 16 z z Using Timer 17 OFF TIMER ON TIMER z z Drying Inside Operation 18 z z Draining 19 z z Continuous Drainage 20 z z Maintenance 21 z z Storage 21 z z Troubleshooting 22 z z Specifications 24 z z Disposal 24 z z This appliance is not intended for ...

Страница 2: ...t to perform continuous operation When you want to set the humidity Reducing blowing sound and performing continuous operation INTELLIGENT LAUNDRY HIGH P 10 P 12 13 HIGH AUTO EASY LOW MILDEW GUARD P 12 14 When you are worried about mildew in the bathroom Tips on Drying Laundry P 11 AIR PURIFIER P 15 When you want to clean the air When you want to dehumidify P 12 13 e01_mj_e160hr_h_cs55 indd 2 2020...

Страница 3: ... unit near heat generating devices such as stoves fan heaters etc The plastic parts may melt and cause fire Do not put your fingers or any long object into the air intake outlet Do not touch the swing louvre The internal fan rotates at high speeds and such actions may result in injury Do not attempt to repair disassemble or modify the unit This may result in fire and or electric shock Refer servic...

Страница 4: ...e unit for special purposes such as preservation of food art or scientific works This may negatively affect the quality of the items stored Do not point airflow from the unit directly at the body for a prolonged period of time Be especially careful when using the unit where there is someone who is unable to adjust the humidity infant child or elderly person If air flow is directed at the body for ...

Страница 5: ...the unit resulting in malfunction Should you incline the unit accidentally contact the place of purchase for advice l Do not carry or store the unit horizontally This may result in malfunctions Such malfunctions are NOT covered under warranty Grasp the plug and remove from the power socket When removing the plug from the power socket do not pull on it diagonally or by the cord as this may cause th...

Страница 6: ...room is thus reduced by repeating the above steps 1 2 3 Re heating Coil Cooling Coil Compressor Water Tank Dry Warm Air Moist Air The amount of dehumidifying becomes less in winter When the temperature and humidity are low the amount of water collected is decreased In winter because the temperature is lower than in summer the effect of the dehumidifier is greatly reduced as shown in the graph on t...

Страница 7: ...2 5 filter has a two layer structure consisting of a white dust filter and a blue deodorizing filter The fine mesh filter can catch PM2 5 and dust The fibres contain a special deodorant and anti bacterial agent antiallergen anti bacterial and degerming This filter cannot remove cigarette smoke and poisonous gases in smoke e g carbon monoxide The water tank may contain water residue at time of purc...

Страница 8: ...ing Monitor P16 Operation Mode Indicator P10 14 Humidity Indicator z z Indicates the approximate humidity LCD Display DRYING INSIDE Switch P18 DRYING INSIDE Lamp FULL Lamp P19 Lights when the tank is full of water AIR PURIFIER Switch P15 AIR PURIFIER Lamp ON OFF TIMER Switch P17 SWING LOUVRE Switch P16 HUMIDITY SELECTION Switch P12 LAUNDRY Switch P10 MODE Switch P12 POWER Switch POWER Lamp z z The...

Страница 9: ... bottom tabs into the unit until they click Strips Tabs 6 Note z z Make sure the PM2 5 filter is attached on the unit If it is not fine dust will enter inside the unit and cause a malfunction Carrying the Unit Hold the handle and move it Casters can be used to move the unit First make sure to remove water from the water tank and close the louvre before carrying the unit z z If casters are unable t...

Страница 10: ...TELLIGENT LAUNDRY Operates for 1 to 12 hours Information z z Remove the water from the tank before operating the unit The unit may stop operating when the tank is full before the laundry is dry z z When it is used with the OFF TIMER operation mode the unit may stop operating before the laundry is dry P17 z z If the room temperature is approximately 5 C or less it becomes difficult for water to eva...

Страница 11: ...ry during drying so that each part can get the blowing air z z Place the dehumidifier so that its back faces the laundry Air blows from the top of the dehumidifier towards the back About the Room for Hanging Clothes z z In a small room it is recommended that the door and window be closed before dehumidifying It is effective not only to dehumidify but also to dry the laundry as soon as possible z z...

Страница 12: ...icator goes out Information z z The dehumidifier remembers the operation mode Even if the power plug is disconnected or the power is turned off the unit restarts at the previous setting z z The humidity cannot be set in modes other than AUTO z z Operation stops when the tank is full To restart operation remove water from the tank If a continuous drainage hose is set the dehumidifier will operate c...

Страница 13: ... motor is decreased It is recommended when you want to dehumidify with lower blower sounds Information z z Sometimes it would take a long time to bring down the humidity depending on opening and closing frequency of the room door or the size or shape of the room To confirm the humidity setting After displaying the current humidity setting is displayed After 3 seconds After approximately 3 seconds ...

Страница 14: ...hen the unit is operating z z The results may vary depending on the size floor and wall materials of the bathroom z z There may be some residual water drops in the places that can collect water z z Mildew growth may still occur due to the fungus type and conditions of the room e g Under the containers of the bathroom deeper inside of closets and behind furniture and places with bad air flow z z Pl...

Страница 15: ...can be locked To prevent children from operating this unit use this function To operate the air purifier only z z AIR PURIFIER The unit cleans the air by passing it through the pre filter and PM2 5 filter The dehumidifier function is disabled Information z The air passes through the PM2 5 filter in all modes cleaning the air even if the AIR PURIFIER lamp is not lit z Cigarette smoke and toxins fou...

Страница 16: ...vre moves slowly through the last 20 of the swing as it takes shorter time to traverse the upward arc than the rear arc when louvre moves at a constant speed Approximately 120 Information z z The level of noise emitted from the unit varies depending on the air blowing direction z z To locate the position the air outlet may stop up to 8 seconds and then start operating again z z If the louvre is to...

Страница 17: ... mode P10 14 Set the DRYING INSIDE auto operation as desired P18 z z Select the louvre swing direction P16 3 Confirm the time setting by pressing the POWER switch z z The timer display lights g The ON TIMER is set If both the timer display and operation mode indicator blink it means the POWER switch is not pressed An alarm blip blip sounds for 1 minute z z The remaining time will decrease one hour...

Страница 18: ...on Press when the POWER is ON The DRYING INSIDE lamp turns off Blip Manual Operation The DRYING INSIDE operation can only start when the POWER is OFF Blip Press while the POWER is OFF z z DRYING INSIDE operation starts The DRYING INSIDE lamp flashes the humidity indicator turns off and the louvre stops in the vertical position DRYING INSIDE Operation z z DRYING INSIDE operation ends The DRYING INS...

Страница 19: ...ons are forbidden except for pressing the POWER switch z z In OFF TIMER operation the FULL lamp is ON as indicator 3 Close the tank lid 4 Check the tank and firmly push it all the way in Tank Make sure the tank is not broken or cracked Confirm that the tank lid and the tank guard are securely attached and push the tank in Sounds Blip Information If the tank is not installed correctly the FULL lamp...

Страница 20: ... oils or lubricants It may damage the unit z z To stop continuous drainage remove the hose put the tank and use z z Do not use the power plug with the power plug being stored in the power cord storage case CAUTION Do not drain water continuously if there is a possibility that temperature around the hose could drop to freezing point Water inside the hose may freeze and prevent the water in the tank...

Страница 21: ...e with a dry cloth Mildew may form in the water tank when the dirt is not removed thoroughly After switching the unit POWER off leave for one day until any residual water inside is removed Then carry out the following steps 1 Perform the DRYING INSIDE operation P18 DRYING INSIDE operation is recommended for prevention of mildew growth inside the unit 2 Hang the power cord on the storage hook or pu...

Страница 22: ...rates intermittently z z When the operation ends the louvre closes The louvre remains open when it stops z z Check to see whether the power cord is off J J Plug the power cord fully into the power socket P9 z z Check to see if anything is blocking the air intake or outlet J J Remove the obstruction P4 z z Check to see if the operation is performed in AUTO and EASY mode J J The unit automatically s...

Страница 23: ...erberates The operating sound suddenly increases in volume The air blowing sound changes in volume The unit produces a simmering sound The unit produces a buzz that sounds intermittently or the compressor does not activate When first used z z The temperature of heat exchanger goes up rapidly causing transient odor z z The discharged moisture may emit an odor It is common that the PM2 5 filter cann...

Страница 24: ... Dehumidifying area According to standards of JEMA Model MJ E160HR H Power supply Single phase 220 V 50 Hz Condition Temperature 26 7 C 30 C Relative humidity 60 80 Dehumidifying capacity 1 16 0 L day 28 0 L day Power consumption 245 W 280 W Recommended room size 2 HIGH 3 67 m2 EASY 45 m2 Water tank capacity Stops automatically at approx 5 5 L Weight 17 4 kg Dimensions H W D 630 mm 410 mm 299 mm D...

Отзывы: