A
B
Check if there is no
disconnection or contact
failure of the connectors
and connector pins of
powercontrol board.
Are error codes
displayed?
“E0” “E1” “E7” “E8”
“A1” “A2” “A3” “A6” “P4”
Refer to “Error Indications and
CorrectiveActions,” and follow
the procedures.
Does the power lamp light
by turning the power on?
Check the continuity of power cord.
Replace the power cord.
Replace the power control board.
Check the current fuse of
power control board (2A/250V).
Does the detective buzzer beep
by turning the power on?
Check if the lamps and LCD
of control panel light.
*
How to put out all lighting(Press
the mode switch and the humidity
selection switch together 4 times
when the power is off. Turn on
the power within 2 seconds.)
*
Check if LED on the operation
control board is down.
(When LED is down, correct it.)
Insert the connector
and connector pins
securely.
Replace the operation control board.
Replace the power control board.
Is “Full lamp” lighting?
Is the tank filled with water ?
Drain water from the tank.
Check the float.
Check the float.
,VWKHIORDWVZLWFKFRPLQJRII
or attached upside-down?
Is the float movement smooth?
Is a magnet attached to the float?
Check the float switch.
Check if there is no disconnection or
contact failure of the connector (P13) and
connector pins of power control board.
Check the continuity between connecter (P13)
terminals when the water tank is equipped.
Normal… Tank full:open
Empty:short
Replace the float switch.
Replace the power control board.
Replace the operation control board.
Does it dehumidify?
Does the blower fan motor rotate?
Insert the connector
and connector pins
securely.
Check the resistance of the
blower fan motor.
Normal:Between yel
ORZDQGEOXHȍ
%HWZHHQEODFNDQGEOXHȍ
Abnormal: Open or short
Check if there is no disconnection
or contact failure of the connector
(P2) and connector pins of power
control board.
Replace the blower fan motor.
Replace the power control board.
Replace the operation control board.
9. Troubleshooting procedure
1) Failure diagnosis flowchart
11
Содержание MJ-E14CG-S1-IT
Страница 2: ...1 Precautions Note This page is extracted from the instruction manual 2 ...
Страница 3: ...Note This page is extracted from the instruction manual 2 Names and Functions of Parts 3 ...
Страница 4: ...Note This page is extracted from the instruction manual 4 ...
Страница 5: ...3 Specifications 4 Outer Dimensions Note This page is extracted from the instruction manual 5 ...
Страница 7: ...2 Board Diagram Power control board Operation control board 7 ...
Страница 18: ...Note This page is extracted from the instruction manual 10 Troubleshooting 18 ...
Страница 19: ...11 Maintenance Note This page is extracted from the instruction manual 19 ...
Страница 20: ...Note This page is extracted from the instruction manual 20 ...
Страница 31: ...31 ...
Страница 36: ...303 B C 305 304 302 301 D 309 308 307 A E 306 Model MJ E14CG S1 IT Exploded View Electrical Parts 36 ...