Do not make drain piping as shown below.

Accumulated 
drain water

Air

Waving

Water 
leakage

Do not raise

Water 
leakage

Water 
leakage

Tip of drain 
hose dipped 
in water

Ditch

At least 
50 mm 
gap

Downward 
slope

Drain 
hose

Soft hose 
I.D. 15 mm

Drain hose

Hard vinyl chloride 

pipe I.D. 30 mm

Insert  

securely

Different 
diameter joint

70 cm or 
more

Fig. 1

Fig. 2

Fig. 3

2-7. DRaIn PIPInG

•  If the extension drain hose has to pass through a room, be sure to wrap it with commercially sold insulation. 

•  The drain hose should point downward for easy drain flow. (Fig. 1)

•  If the drain hose provided with the indoor unit is too short, connect it with drain hose (I) that should be provided at your site. (Fig. 2)

•  When connecting the drain hose to the hard vinyl chloride pipe, be sure to insert it securely into the pipe. (Fig. 3)

2-8. FRont PanEl InstallatIon

1) Open the rear horizontal vane.

2) Attach the panel. Make sure that the catches are engaged.

3) Fix the panel with screws.

4) Insert the bottom part of the front panel.

5) Push 3 places on the upper part of the front panel to close it.

Wrap the felt tape (11) tightly around the pipes and hose starting near where 

the pipes and hose are routed from the indoor unit. (The overlap width of the felt 

tape (11) should not be more than 1/2 of the tape width.)

Felt tape (11)

Start wrapping the piping tape (G) around 

the pipes and hose 10 mm inside the 
indoor unit.

Fasten the end of the felt tape (11) with 

a bandage stopper.

Make sure that the drain hose 
is not routed upward.

FOR LEFT OR LEFT-REAR PIPING
Bundle the connecting pipes and drain hose together, and then wrap them in felt 

tape (11).

Cut and use the lower side panels on the left and right sides of the indoor unit as 
shown below.

Smooth the cut edges of the side panels so that they will not damage the insulation 

coating.

•  For left or right piping  

•  Installing flush against a wall with molding

Molding

Cut the lower side panels to 
match the height of the molding.

Fig. 5

Projection

Make sure to 

hook the catch.

Drain hose

Pull the hose to 

confirm 

it is con-

nected securely.

Fig. 4

the Drain hose is removed at installation.

•  When routing the drain piping, make sure that the drain 

hose (1) is routed as shown. (Fig. 4)

•  Insert the drain hose all the way to the base of the drain 

pan (end connection). (Fig. 5) 

 

Make sure that the catch of the drain hose is securely 

hooked onto the projection on the hose fitting of the drain 

pan. 

•  After connecting the drain hose, be sure to pull the hose to 

confirm that it is connected securely. 

Front panel

Indoor unit

Indoor unit

Panel

Panel

2-9. ConnECtInG an IntERFaCE (option)/ConnECtoR CaBlE (option) to tHE aIR ConDItIonER

Thin part of the connecting cable. 
Place this part where customers 
cannot touch it.

Room air 
conditioner

Main body of an interface

Thick part of the connecting cable

Indoor control
P.C. board

CN105 for interface 
CN104 for connector cable

•  Connect an interface/connector cable to the indoor control P.C. 

board of an air conditioner with a connecting cable.

•  Cutting or extending the connecting cable of the interface/

connector cable results in defects in connecting. Do not 

bundle the connecting cable together with power supply cord, 

indoor/outdoor connecting wire, and/or earth wire. Keep as 
much distance as possible between the connecting cable and 
those wires.

•  The thin part of the connecting cable should be stored and 

placed where customers cannot touch it.

Rear horizontal 
vane

JG79A867H01_en.indd   5

2014/02/07   15:45:02

Содержание MFZ-KJ25VE

Страница 1: ... TYPE AIR CONDITIONERS MFZ KJ25VE MFZ KJ35VE MFZ KJ50VE English InstallatIon Manual For INSTALLER When installing multi units refer to the installation manual of the multi unit for outdoor unit installation ...

Страница 2: ...ls and piping materials for installation The pressure of R410A is 1 6 times more than R22 Not using appropriate tools or materials and incom plete installation could cause the pipes to burst or injury n When pumping down the refrigerant stop the compressor before disconnecting the refriger ant pipes If the refrigerant pipes are disconnected while the compressor is running and the stop valve is ope...

Страница 3: ...ess than 7 m Additional refrigerant A pipe length m 7 8 Insulation material Heat resisting foam plastic 0 045 specific gravity 9 Be sure to use the insulation of specified thickness Ex cessive thickness may cause incorrect installation of the indoor unit and insufficient thickness may cause dew drip page Model Power supply 1 Wire specifications 2 Pipe size thickness 3 4 Indoor unit Outdoor unit Ra...

Страница 4: ...WARD PIPING The following figure is a view of the bottom of the indoor unit from above FOR REAR OR LEFT REAR PIPING The following figure is a front view of the indoor unit installation location FOR LEFT PIPING FOR RIGHT PIPING HolE PosItIons ø65 mm KJ25 35 ø75 mm KJ50 5 7 mm 2 3 InDooR unIt PREPaRatIon Remove the front panel of the indoor unit 1 Push down the tab on the both sides of the unit to o...

Страница 5: ...door unit and process the end of the wire 3 Loosen terminal screw and connect first the earth wire then indoor outdoor unit connecting wire A to the terminal block Be careful not to make mis wiring Fix the wire to the terminal block securely so that no part of its core is appeared and no external force is conveyed to the connecting section of the terminal block 4 Firmly tighten the terminal screws...

Страница 6: ...tape 11 Cut and use the lower side panels on the left and right sides of the indoor unit as shown below Smooth the cut edges of the side panels so that they will not damage the insulation coating For left or right piping Installing flush against a wall with molding Molding Cut the lower side panels to match the height of the molding Fig 5 Projection Make sure to hook the catch Drain hose Pull the ...

Страница 7: ...me manner applied for indoor unit For tightening use a torque wrench or spanner and use the same tightening torque applied for indoor unit 3 4 INSULATION AND TAPING 1 Cover piping joints with pipe cover 2 For outdoor unit side surely insulate every piping including valves 3 Using piping tape G apply taping starting from the entry of outdoor unit Stop the end of piping tape G with tape with adhesiv...

Страница 8: ...et temperature 24ºC will start 2 To stop operation press the E O SW several times until all LED lamps turn off Refer to operating instructions for details Checking the remote infrared signal reception Press the ON OFF button on the remote controller 12 and check that an electronic sound is heard from the indoor unit Press the ON OFF button again to turn the air conditioner off Once the compressor ...

Страница 9: ......

Страница 10: ......

Страница 11: ......

Страница 12: ...HEAD OFFICE TOKYO BLDG 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN JG79A867H01 ...

Отзывы: