4
4. INDOOR UNIT INSTALLATION
4-1
INDOOR UNIT MOUNTING BRACKET INSTALLATION
• Install the bracket firmly to the wall structure (stud, etc.).
• Use a level to install the mounting bracket horizontally.
• Install the indoor unit 150 mm or below from the floor.
Indoor unit mounting bracket
7
To prevent the indoor unit mounting bracket
7
from vi-
brating slightly, be sure to fasten the bracket at the holes
indicated by
b
. In addition, fasten the bracket at the holes
indicated by
f
if possible.
131
131
14
(600)
586
200
(700)
4-2
INDOOR UNIT PREPARATION
• Press the 2 positions indicated by the arrows
e
and open the front grille.
• Open the front grille and remove the two screws.
• Open the horizontal vane for the upper air outlet, push the top of the front panel in three locations, and then
pull the top of the grille away from the indoor unit.
• Lift up the front grille to remove it.
Screws
4-4
CONNECTING WIRE SPECIFICATIONS
• Use special room air conditioning circuit.
Indoor/outdoor unit connecting
Cable 4-core 1.5 mm
2
, in conformity
wire Specification
with Design 245 IEC 57.
Warning:
Never cut the indoor and outdoor unit connecting wire and connect it to other wires. It may cause a fire.
4-3
INDOOR UNIT INSTALLATION
• Hook the top of the indoor unit on the indoor unit mounting bracket
7
.
• Use the included wood screws
9
and washer
0
, and fasten the indoor unit at 2 locations(
e
) each at the top
and the middle of the unit.
674
333
363
210
01HM05A309_RAC-IM_en.pm6
4/6/05, 1:38 PM
4
Содержание MFZ-KA25VA
Страница 12: ...01HM05A309_RAC IM_cover pm6 4 6 05 1 36 PM 2 ...
Страница 24: ...02HM05A309_RAC IM_cover_de pm6 4 6 05 1 49 PM 2 ...
Страница 36: ...03HM05A309_RAC IM_cover_fr pm6 4 6 05 1 50 PM 2 ...
Страница 48: ...04HM05A309_RAC IM_cover_nl pm6 4 6 05 1 52 PM 2 ...
Страница 60: ...05HM05A309_RAC IM_cover_es pm6 4 6 05 1 53 PM 2 ...
Страница 72: ...06HM05A309_RAC IM_cover_it pm6 4 6 05 1 54 PM 2 ...
Страница 84: ...07HM05A309_RAC IM_cover_el pm6 4 6 05 1 56 PM 2 ...
Страница 96: ...08HM05A309_RAC IM_cover_pt pm6 4 6 05 1 58 PM 2 ...
Страница 108: ...09HM05A309_RAC IM_cover_da pm6 4 6 05 1 59 PM 2 ...
Страница 120: ...10HM05A309_RAC IM_cover_sw pm6 4 6 05 2 28 PM 2 ...
Страница 132: ...11HM05A309_RAC IM_cover_tr pm6 4 6 05 2 30 PM 2 ...