274
4 APPLICABLE FUNCTIONS
4.10 Torque limit [A]
Torque limit selection
The torque limit can be selected using TL (External torque limit selection).
In addition, by turning on TL1 (Internal torque limit selection) through servo parameters, [Pr. PC35 Internal torque limit 2] can
be selected.
However, if the value for [Pr. PA11] or [Pr. PA12] is less than the limit value selected using TL/TL1, the value for [Pr. PA11] or
[Pr. PA12] is enabled.
*1 0: off, 1: on
Checking "Limiting torque" status
TLC (Limiting torque) turns on when the servo motor torque reaches the torque that was limited by the forward rotation torque
limit, reverse rotation torque limit, internal torque limit, or analog torque limit.
Input device
Limit value status
Enabled torque limit
TL1
TL
CCW power running/CW
regeneration
CW power running/CCW
regeneration
0
0
[Pr. PA11]
[Pr. PA12]
0
1
TLA > [Pr. PA11]
TLA > [Pr. PA12]
[Pr. PA11]
[Pr. PA12]
TLA < [Pr. PA11]
TLA < [Pr. PA12]
TLA
TLA
1
0
[Pr. PC35] > [Pr. PA11]
[Pr. PC35] > [Pr. PA12]
[Pr. PA11]
[Pr. PA12]
[Pr. PC35] < [Pr. PA11]
[Pr. PC35] < [Pr. PA12]
[Pr. PC35]
[Pr. PC35]
1
1
TLA > [Pr. PC35]
[Pr. PC35]
[Pr. PC35]
TLA < [Pr. PC35]
TLA
TLA