1 SPECIFICATIONS
1.4 Servo amplifier standard specifications
11
1
Environment
*1 Refer to "Restrictions when using this product at altitude exceeding 1000 m and up to 2000 m" in the following manual for using the
product at altitude exceeding 1000 m.
MR-J5 User's Manual (Hardware)
Item
Operation
Transportation
Storage
Ambient
temperature
0
˚
C to 60
˚
C (non-freezing)
Class 3K3 (IEC 60721-3-3)
-25
˚
C to 70
˚
C (non-freezing)
Class 2K12 (IEC 60721-3-2)
-25
˚
C to 70
˚
C (non-freezing)
Class 1K4 (IEC 60721-3-1)
Ambient humidity
5 %RH to 95 %RH (non-condensing)
5 %RH to 95 %RH (non-condensing)
5 %RH to 95 %RH (non-condensing)
Ambience
Indoors (no direct sunlight); no corrosive gas, inflammable gas, oil mist or dust
Altitude/
atmospheric
pressure
Altitude: 2000 m or less
Transportation conditions: Must be
transported by ground/sea, or air at an
atmospheric pressure of 700 hPa or more.
Atmospheric pressure: 700 hPa to 1060
hPa
(equivalent to the altitude of -400 m to 3000
m.)
Vibration resistance
When there is continuous vibration:
10 Hz to 57 Hz, displacement amplitude
0.075 mm
57 Hz to 150 Hz, acceleration amplitude
9.8 m/s
2
Class 3M1 (IEC 60721-3-3)
When there is continuous vibration:
10 Hz to 55 Hz, acceleration amplitude 5.9
m/s
2
2 Hz to 8 Hz, displacement amplitude (half
amplitude) 7.5 mm
8 Hz to 200 Hz, acceleration amplitude 20
m/s
2
Class 2M3 (IEC 60721-3-2)
2 Hz to 9 Hz, displacement amplitude (half
amplitude) 1.5 mm
9 Hz to 200 Hz, acceleration amplitude 5
m/s
2
Class 1M2 (IEC 60721-3-1)
Dielectric strength
Between main circuit (power supply/power terminal) and PE: 1500 V AC, 1 minute, 50 Hz/60 Hz
Insulation
resistance
Between main circuit (power supply/power terminal) and PE: 0.5 M
Ω
or more (with a 500 V DC megger)