128
4 APPLICABLE FUNCTIONS
4.3 Drive recorder
*1 Not available on this servo amplifier.
Waveform recording inapplicable alarm list
Alarms that are not covered in the alarm history are not subject to recording by the drive recorder. For details, refer to the
following manual.
MR-JET User's Manual (Troubleshooting)
The alarms shown in the following table are saved in the alarm history, but are not subject to recording by the drive recorder.
The drive recorder does not operate in this case.
In addition, data may not be recorded when the following alarms occur depending on the circumstances of the alarm
occurrence.
AL. 046
Servo
motor
speed +
Torque
Current
command
Internal
temperature
of encoder
Temperature
of servo
motor
thermistor
Bus voltage
Effective
load ratio
32 ms
32768 ms
CSON
EM2/EM1
ALM2
INP
MBR
RD
IPF
AL. 050
Servo
motor
speed +
Torque
Current
command
Droop
pulses (100
pulses) +
Overload
alarm
margin
Bus voltage
Effective
load ratio
32 ms
32768 ms
CSON
EM2/EM1
ALM2
INP
MBR
RD
IPF
AL. 051
Servo
motor
speed +
Torque
Current
command
Droop
pulses (100
pulses) +
Overload
alarm
margin
Bus voltage
Effective
load ratio
32 ms
32768 ms
CSON
EM2/EM1
ALM2
INP
MBR
RD
IPF
AL. 052
Servo
motor
speed +
Torque
Current
command
Droop
pulses (100
pulses) +
Speed
command
Bus voltage
Excessive
error alarm
margin
2 ms
2048 ms
CSON
EM2/EM1
ALM2
INP
MBR
RD
TLC
Alarm No.
Name
010.1
Voltage drop in the control circuit power
012
Memory error 1
016
Encoder initial communication error 1
017
Board error
019
Memory error 3
01A
Servo motor combination error
01E
Encoder initial communication error 2
01F
Encoder initial communication error 3
025
Absolute position erased
119
Memory error 4
Alarm No.
Name
013
CPU error
014
Control process error
Trigger
condition
Data 1
Data 2
Data 3
Data 4
Data 5
Data 6
Data 7
Data 8
Sampling
cycle
Measurement
time
Содержание MELSERVO-JET MR-JET-G-N1 Series
Страница 1: ...MR JET User s Manual Function MR JET _G MR JET _G N1 Mitsubishi Electric AC Servo System ...
Страница 2: ......
Страница 161: ......