9 PDS Control Objects
9.2 [Statusword (Obj. 6041h)]
81
9
■
[Bit 13: OMS]
*1 Available on servo amplifiers with firmware version A5 or later.
*2 Available on servo amplifiers with firmware version B0 or later.
Setting value
Name
Description
1 (pp)
Following error
0: No following error
1: Following error
Max slippage error
0: Maximum slippage not reached
1: Maximum slippage reached (not supported)
Max slippage is the maximum slippage of the asynchronous servo motor.
4 (tq)
6 (hm)
Homing error
Refer to the following.
8 (csp)
Following error
0: No following error
1: Following error
When the time set in [Following error time out (Obj. 6066h)] elapses in a state where the value of [Following error
actual value (Obj. 60F4h)] exceeds the value set in [Following error window (Obj. 6065h)], this bit becomes "1".
9 (csv)
10 (cst)
-104 (ct)