6 OPTIONS AND PERIPHERAL EQUIPMENT
6.11 Power factor improving DC reactor
*1 Use this for grounding.
*2 When using the power factor improving DC reactor, remove the short-circuit bar between P3 and P4.
*3 Selection requirements for the wire size are as follows.
Wire type: 600 V Grade heat-resistant polyvinyl chloride insulated wire (HIV wire)
Construction requirements: Single wire set in midair
Servo amplifier
Power factor
improving
DC reactor
Dimensions [mm]
Terminal
size
Mass
[kg]
Wire [mm
2
W
W1
H
D
D1
D2
D3
d
MR-J5-200_4_
FR-HEL-H3.7K
86
55
120
95
89
69
45
M4
M4
2.3
2 (AWG 14)
MR-J5-350_4_
FR-HEL-H7.5K
96
60
128
105
100
80
50
M5
M4
3.5
2 (AWG 14)
W1
W ± 2.5
D2
D1 ± 1
H ± 2.5
P
P1
*2
P3
P4
P1
P
FR-HEL-H
4-d mounting hole
*1
D or less
(D3)
Servo amplifier
5 m or less