Objects required for each mode are shown in the following table.
RxPDO
*1
: Mapping required
: Mapping recommended
: Mapping not required
TxPDO
*1
: Mapping required
: Mapping recommended
: Mapping not required
Object name (Index)
Mode
csp
csv
cst
pp
pv
tq
hm
Controlword (6040h)
Control DI 1 (2D01h) Gain switching
Control DI 2 (2D02h) Proportional control
Control DI 3 (2D03h)
Target position (607Ah)
Target velocity (60FFh)
Target torque (6071h)
Profile velocity (6081h)
Profile acceleration (6083h)
Profile deceleration (6084h)
Torque slope (6087h)
Velocity limit value (2D20h)
Object name (Index)
Mode
csp
csv
cst
pp
pv
tq
hm
Statusword (6041h)
Status DO 1 (2D11h)
Status DO 2 (2D12h)
Status DO 3 (2D13h)
Position actual value (6064h)
Following error actual value (60F4h)
Velocity actual value (606Ch)
Torque actual value (6077h)