15 USING A DIRECT DRIVE MOTOR
15.3 Operation and functions
507
15
■
Torque deviation error detection
Set [Pr. PL04] to "_ _ _ 4" to enable the torque deviation error detection.
When you compare the command torque ( 5)) and the feedback torque ( 6)) in "Outline of servo control error detection
function", if the deviation is more than the value of [Pr. PL07 Torque/thrust deviation error detection level] (1% to 1000%), [AL.
42.3 Servo control error by torque/thrust deviation] will occur and the direct drive motor will stop. The initial value of this
detection level is 100%. Replace the set value as required.
For "Outline of servo control error detection function", refer to the following.
Page 506 Outline of servo control error detection function
■
Detecting multiple deviation errors
When setting [Pr. PL04] as shown below, multiple deviation errors can be detected. For the error detection methods, refer to
the following.
Page 506 Position deviation error detection
Page 506 Speed deviation error detection
Page 507 Torque deviation error detection
[Pr. PL04]
Torque deviation error detection enabled
4
[Pr. PL04]
Position deviation
error detection
Setting
value
Speed deviation
error detection
Torque deviation
error detection
1
5
6
7
3
2
4
¨
«
«
«
«
«
«
«
«
«
¨
¨
¨
¨
¨
¨
¨
¨
¨
¨
¨