378
11 OPTIONS AND PERIPHERAL EQUIPMENT
11.5 FR-CV-(H) power regeneration common converter
*1 This is the time when the protective function of the FR-CV-H is activated. The protective function of the servo amplifier is activated in the
time indicated in the following section.
Page 311 Overload protection characteristics
*2 The specified value is the power supply capacity of FR-CV-H. The total power supply capacities of the connected servo amplifiers are
actually required.
Item
Power regeneration common converter
FR-CV-H_
7.5K
11K
15K
22K
30K
37K
55K
Total of connectable servo amplifier capacities
[kW]
3.75
5.5
7.5
11
15
18.5
27.5
Maximum servo amplifier capacity [kW]
3.5
5
7
11
15
15
22
Output
Total of connectable servo motor
rated currents [A]
17
23
31
43
57
71
110
Regenerative
braking torque
Short-time
rating
Total capacity of applicable servo motors, 300% torque, 60 s
Continuous
rating
100% torque
Power supply
Rated input AC voltage/frequency
3-phase 380 V AC to 480 V AC, 50 Hz/60 Hz
Permissible AC voltage
fluctuation
3-phase 323 V AC to 528 V AC, 50 Hz/60 Hz
Permissible frequency fluctuation
5%
Power supply capacity
[kVA]
17
20
28
41
52
66
100
IP rating (JEM 1030), cooling method
Open type (IP00), forced cooling
Environment
Ambient temperature
-10 °C to 50 °C (non-freezing)
Ambient humidity
5 %RH to 90 %RH (non-condensing)
Ambience
Indoors (no direct sunlight), free from corrosive gas, flammable gas, oil mist, dust, and dirt
Altitude, vibration resistance
1000 m or less above sea level, 5.9 m/s
2
Molded-case circuit breaker or earth-leakage
current breaker
30AF
15A
30AF
20A
30AF
30A
50AF
50A
60AF
60A
100AF
75A
100AF
100A
Magnetic contactor
S-N20
S-T21
S-N20
S-T21
S-N20
S-T21
S-N25
S-T25
S-N35
S-T35
S-N50
S-T50
S-N65
S-T65
Содержание MELSERVO-J4 series
Страница 2: ......
Страница 605: ...APPX Appendix 6 EC declaration of conformity 603 A ...
Страница 638: ...636 APPX Appendix 14 Encoder output pulse setting method MEMO ...
Страница 645: ......