144
5 MODULE DEDICATED INSTRUCTION
5.4 Network Dedicated Instruction
Message (user-specified data) communication
J(P)_SEND, G(P)_SEND
The following instruction can go in the dotted squares.
J_SEND, JP_SEND, G_SEND, GP_SEND
■
Executing condition
■
Argument
*1 Local devices and file registers per program cannot be used as setting data.
Processing details
This instruction sends data to another station.
Instruction
Executing condition
J_SEND
G_SEND
JP_SEND
GP_SEND
Input/output
argument
Name
Description
Data type
Input argument
EN
Executing condition
Bit
Jn*
Network number of the host station (1 to 239, 254)
254: Network specified in "Valid module during
other station access"
ANY16
Un*
Start I/O number of the module
(00 to FE: Higher two digits when expressing the I/
O number in three digits)
ANY16
s1
Variable that stores control data
Array of ANY16 [0..17]
s2
Start number of the host station's device that stores
write data
ANY16
Output argument
ENO
Execution result
Bit
d
Variable that turns ON upon completion of the
instruction
d[1] also turns ON at the time of error completion.
Array of bit [0..1]
Setting
data
Internal device
R, ZR
J
\
U
\G
Zn
Constant
Others
Bit
Word
Bit
Word
(s1)
(s2)
(d)
CC IE F
CC IE C
NET/H
Ether
Structured ladder/FBD
EN
ENO
Jn*
d
s1
s2
J_SEND
EN
ENO
Un*
d
s1
s2
G_SEND
ST
J_SEND
(EN, Jn*, s1, s2, d);
ENO:=
G_SEND
(EN, Un*, s1, s2, d);
ENO:=