2. SYSTEM CONFIGURATION
2
−
4
POINT
(1) The interface board and interface card cannot be used together.
(2) On some personal computers, the digital oscilloscope may not perform
sampling.
In that case, check the BIOS's ISA device memory and IRQ settings. (For
the BIOS settings, refer to the manual of your personal computer.)
(3) If, after SSCNET communication has been made, you remove the
interface board and boot the personal computer without that board being
reinstalled, Windows NT/98 may not start or may not run properly.
When removing the interface board from the personal computer, you
need to stop the SSCNET communication driver.
For the way to stop, refer to "4.5 Stopping the SSCNET Communication
Driver".
(4) You cannot fit and use the A30BD-PCF and A10BD-PCF interface
boards together.
(5) The interface boards can be used in the following environment.
Windows 98
Windows NT
Windows 2000
A30BD-PCF interface board
(ISA bus built-in type)
A10BD-PCF interface board
(PCI bus built-in type)
Usable:
Unusable:
(6) When you use the plural A10BD-PCF interface boards in Windows NT,
make the BIOS setting not to overlap the IRQs of each board.