182
CHAPTER 13
READING/WRITING DEVICE DATA OF
ANOTHER STATION CPU BY IP
ADDRESS SPECIFICATION
Dedicated instructions allow the CPU module on the host station to read/write device data from/to the CPU module on
another station.
Note 13.1
13.1
Instructions to Read/write Device Data of Another
Station CPU by IP Address Specification
This section describes the instructions for reading/writing device data from/to the CPU module on another station by
specifying an IP address.
(1) List of instructions
The following table lists the instructions associated with reading/writing device data from/to the CPU module on
another station by specifying an IP address:
The SP.READ/SP.WRITE instructions cannot be used in an interrupt program or fixed scan execution type program.
Note
13.1
Reading/writing device data from/to the CPU module on another station by specifying an IP address is available with
QnUDVCPU only.
Before reading/writing device data from/to the CPU module on another station by specifying an IP address is used, check
the versions of the CPU modules (i.e., the CPU modules of the host and other stations) and the versions of the
programming tools. (
Instruction
Description
Reference
SP.READ
Reads device data from another station's CPU module
device identified by the specified IP address.
SP.WRITE
Writes device data to another station's CPU module
device identified by the specified IP address.
Universal
Ethernet
D50
D500
CPU module
on the host station
IP address setting
IP address
IP address setting
IP address
Programming
Device
Device
Receive data
Send data
CPU module
on another station