14 TROUBLESHOOTING
14.5 List of Error Codes
527
14
14.5
List of Error Codes
Error
code
Error name
Cause and description
Action
1080H
Flash ROM
write number
error
Writing to the flash ROM has been executed more than 25
times in a row with the program.
[Operation of when the error has occurred]
Data is not written to the flash ROM.
• Correct the program so that writing to the flash ROM is not
executed in a row. (The number of write accesses to the
flash ROM can be checked with [Md.19] No. of write
accesses to flash ROM.)
• If this error has occurred when the module is used correctly,
data can be written after the error is reset, the system is
powered off and on, or the CPU module is reset.
17C3H
Module
extension
parameter
writing error
The "Extended parameter storage setting" is set to "CPU",
and error has occurred while executing module data backup
function or module data initialization function.
[Operation of when the error has occurred]
The module data backup function or the module data
initialization function does not operate.
Check the free space on the data memory of the control CPU
and the SD memory card, and execute the module data
backup function or the module data initialization function.
17C4H
The "Extended parameter storage setting" is set to "CPU",
and execute the module data backup function or the module
data initialization function when the CPU module is in the
RUN state.
[Operation of when the error has occurred]
The module data backup function or the module data
initialization function does not operate.
Execute the module data backup function or the module data
initialization function when the CPU module is in the STOP
state.
1800H
Interrupt factor
setting error
The value outside the setting range is set in the interrupt
factor setting.
[Operation of when the error has occurred]
The interrupt function does not operate.
Correct the value of the interrupt factor setting and turn on
PLC READY signal [Y0].
1801H
Axis No. for
interrupt factor
setting error
The value outside the setting range is set in the axis No. for
interrupt factor.
[Operation of when the error has occurred]
The interrupt function does not operate.
Correct the value of the axis No. for interrupt factor and turn
on PLC READY signal [Y0].
1860H
Dedicated
instruction error
The G.ABRST
instruction has been executed when the
value other than 0 is stored in the status. (at the
communication start with a servo amplifier)
[Operation of when the error has occurred]
The positioning function corresponding to each dedicated
instruction is not executed.
Set 0 in the status when executing the G.ABRST
instruction.
For details, refer to
MELSEC iQ-R Programming Manual
(Instructions, Standard Functions/Function Blocks)
1861H
The status has been changed during absolute position
restoration (during communication with a servo amplifier) by
the G.ABRST
instruction.
[Operation of when the error has occurred]
The positioning function corresponding to each dedicated
instruction is not executed.
Do not change the status during absolute position restoration
by the G.ABRST
instruction. For details, refer to
MELSEC iQ-R Programming Manual (Instructions,
Standard Functions/Function Blocks)
1862H
The GP.PSTRT
instruction has been executed when a
value other than 1 to 600, 7000 to 7004, and 9001 to 9004 is
stored in the start No.
[Operation of when the error has occurred]
The positioning function corresponding to each dedicated
instruction is not executed.
Choose the start number within the setting range when
executing the GP.PSTRT
instruction. For details, refer to
MELSEC iQ-R Programming Manual (Instructions,
Standard Functions/Function Blocks)
1863H
The GP.TEACH
instruction has been executed when a
value other than 0 and 1 is set in the teaching data selection.
[Operation of when the error has occurred]
The positioning function corresponding to each dedicated
instruction is not executed.
Set 0 or 1 in the teaching data selection when executing the
GP.TEACH
instruction. For details, refer to
MELSEC iQ-
R Programming Manual (Instructions, Standard Functions/
Function Blocks)
1864H
The GP.TEACH
instruction has been executed when a
value other than 1 to 600 is set in the teaching positioning
data No.
[Operation of when the error has occurred]
The positioning function corresponding to each dedicated
instruction is not executed.
Set the value within the setting range in the teaching
positioning data No. (1 to 600) when executing the
GP.TEACH
instruction. For details, refer to
MELSEC iQ-
R Programming Manual (Instructions, Standard Functions/
Function Blocks)
1865H
The G.ABRST
, GP.PSTRT
, or GP.TEACH
instruction
has been executed with a non-existent axis being specified as
the target of the instruction.
[Operation of when the error has occurred]
The positioning function corresponding to each dedicated
instruction is not executed.
Do not specify a non-existent axis as the target of the
instruction when executing the G.ABRST
, GP.PSTRT
, or
GP.TEACH
instruction. For details, refer to
MELSEC iQ-
R Programming Manual (Instructions, Standard Functions/
Function Blocks)
Содержание MELSEC iQ-R RD75P4
Страница 1: ...MELSEC iQ R Positioning Module User s Manual Application RD75P2 RD75P4 RD75D2 RD75D4 ...
Страница 2: ......
Страница 13: ...11 MEMO ...
Страница 19: ...17 CONTENTS INDEX 588 REVISIONS 592 WARRANTY 593 TRADEMARKS 594 ...
Страница 498: ...496 13 PROGRAMMING 13 2 List of Labels Used ...
Страница 503: ...13 PROGRAMMING 13 4 Program Example 501 13 ...
Страница 511: ...13 PROGRAMMING 13 4 Program Example 509 13 Torque change program Step operation program Skip program ...
Страница 512: ...510 13 PROGRAMMING 13 4 Program Example Teaching program Continuous operation interrupt program ...
Страница 513: ...13 PROGRAMMING 13 4 Program Example 511 13 Target position change program Absolute position restoration program ...
Страница 514: ...512 13 PROGRAMMING 13 4 Program Example Restart program Parameter data initialization program ...
Страница 515: ...13 PROGRAMMING 13 4 Program Example 513 13 Flash ROM write program Error reset program ...
Страница 516: ...514 13 PROGRAMMING 13 4 Program Example Stop program ...
Страница 565: ...APPENDICES Appendix 4 Operation Examples of When the Remote Head Module Is Mounted 563 A ...
Страница 568: ...566 APPENDICES Appendix 4 Operation Examples of When the Remote Head Module Is Mounted Common program ...
Страница 584: ...582 APPENDICES Appendix 4 Operation Examples of When the Remote Head Module Is Mounted Restart program ...
Страница 587: ...APPENDICES Appendix 4 Operation Examples of When the Remote Head Module Is Mounted 585 A Stop program ...
Страница 597: ......