12 DATA USED FOR POSITIONING CONTROL
12.3 Basic Setting
387
12
[Pr.62] Electronic gear selection
Select an electronic gear (16 bits or 32 bits) to use.
The addresses used by the buffer memory areas shown below depend on the setting of this area.
■
Buffer memory address
The following table shows the buffer memory address of this area.
■
Default value
The default value is 0: 16 bits for all the axes.
[Pr.2] No. of pulses per rotation (32 bits) (Ap)
Set the number of pulses required for a rotation of the motor shaft with 32 bits. When [Pr.62] Electronic gear selection is set to
1: 32 bits, this area is valid. When the resolution per rotation of the servomotor of the servo amplifier used exceeds 65535
pulses, set the number of pulses per rotation with this area.
■
Buffer memory address
The following table shows the buffer memory address of this area.
■
Setting range
The setting range is 1 to 200000000.
■
Default value
The default value is 20000 for all the axes.
Electronic gear selection
Setting value
16 bits
0
32 bits
1
Setting value of [Pr.62]
Electronic gear selection
Address of [Pr.2] No. of pulses per rotation
Address of [Pr.3] Movement amount per
rotation
0: 16bits
• Axis 1: 1
• Axis 2: 151
• Axis 3: 301
• Axis 4: 451
• Axis 1: 2
• Axis 2: 152
• Axis 3: 302
• Axis 4: 452
1: 32bits
• Axis 1: 102, 103
• Axis 2: 252, 253
• Axis 3: 402, 403
• Axis 4: 552, 553
• Axis 1: 104, 105
• Axis 2: 254, 255
• Axis 3: 404, 405
• Axis 4: 554, 555
Buffer memory name
Axis 1
Axis 2
Axis 3
Axis 4
[Pr.62] Electronic gear selection
100
250
400
550
Buffer memory name
Axis 1
Axis 2
Axis 3
Axis 4
[Pr.2] No. of pulses per rotation (32 bits) (Ap)
102
252
402
552
103
253
403
553
Содержание MELSEC iQ-R RD75P4
Страница 1: ...MELSEC iQ R Positioning Module User s Manual Application RD75P2 RD75P4 RD75D2 RD75D4 ...
Страница 2: ......
Страница 13: ...11 MEMO ...
Страница 19: ...17 CONTENTS INDEX 588 REVISIONS 592 WARRANTY 593 TRADEMARKS 594 ...
Страница 498: ...496 13 PROGRAMMING 13 2 List of Labels Used ...
Страница 503: ...13 PROGRAMMING 13 4 Program Example 501 13 ...
Страница 511: ...13 PROGRAMMING 13 4 Program Example 509 13 Torque change program Step operation program Skip program ...
Страница 512: ...510 13 PROGRAMMING 13 4 Program Example Teaching program Continuous operation interrupt program ...
Страница 513: ...13 PROGRAMMING 13 4 Program Example 511 13 Target position change program Absolute position restoration program ...
Страница 514: ...512 13 PROGRAMMING 13 4 Program Example Restart program Parameter data initialization program ...
Страница 515: ...13 PROGRAMMING 13 4 Program Example 513 13 Flash ROM write program Error reset program ...
Страница 516: ...514 13 PROGRAMMING 13 4 Program Example Stop program ...
Страница 565: ...APPENDICES Appendix 4 Operation Examples of When the Remote Head Module Is Mounted 563 A ...
Страница 568: ...566 APPENDICES Appendix 4 Operation Examples of When the Remote Head Module Is Mounted Common program ...
Страница 584: ...582 APPENDICES Appendix 4 Operation Examples of When the Remote Head Module Is Mounted Restart program ...
Страница 587: ...APPENDICES Appendix 4 Operation Examples of When the Remote Head Module Is Mounted 585 A Stop program ...
Страница 597: ......