198
5 MANUAL CONTROL
5.4 Manual Pulse Generator Operation
Parameters required for the manual pulse generator operation
To perform the manual pulse generator operation, parameters must be set. The following table shows the required parameters
for performing the manual pulse generator operation. When only the manual pulse generator operation is performed,
parameters not described below are not required. (Set the value within the setting range, such as the initial value.)
: Always set
: Set as required (set a value within the setting range such as the initial value when the item is not used.)
• Setting parameters is the common operation for all controls using the RD75. When performing another
control (Major positioning control, Advanced positioning control, or OPR control), configure the setting items
required for the control.
• Parameters are set for each axis. However, the manual pulse generator input logic (b8) of [Pr.22] and
[Pr.24] are set only for the axis 1. (The setting for the axes 2 to 4 is ignored.)
• For details on the settings, refer to the following.
Setting item
Setting
requirement
Parameter
[Pr.1]
Unit setting
[Pr.2]
No. of pulses per rotation (Ap) (Unit: pulse)
[Pr.3]
Movement amount per rotation (Al) (Unit: pulse)
[Pr.4]
Unit magnification (Am)
[Pr.5]
Pulse output mode
[Pr.6]
Rotation direction setting
[Pr.11]
Backlash compensation amount (Unit: pulse)
[Pr.12]
Software stroke limit upper limit value (Unit: pulse)
[Pr.13]
Software stroke limit lower limit value (Unit: pulse)
[Pr.14]
Software stroke limit selection
[Pr.15]
Software stroke limit valid/invalid setting
[Pr.17]
Torque limit setting value (Unit: %)
[Pr.22]
Input signal logic selection
[Pr.23]
Output signal logic selection
[Pr.24]
Manual pulse generator input selection
Содержание MELSEC iQ-R RD75P4
Страница 1: ...MELSEC iQ R Positioning Module User s Manual Application RD75P2 RD75P4 RD75D2 RD75D4 ...
Страница 2: ......
Страница 13: ...11 MEMO ...
Страница 19: ...17 CONTENTS INDEX 588 REVISIONS 592 WARRANTY 593 TRADEMARKS 594 ...
Страница 498: ...496 13 PROGRAMMING 13 2 List of Labels Used ...
Страница 503: ...13 PROGRAMMING 13 4 Program Example 501 13 ...
Страница 511: ...13 PROGRAMMING 13 4 Program Example 509 13 Torque change program Step operation program Skip program ...
Страница 512: ...510 13 PROGRAMMING 13 4 Program Example Teaching program Continuous operation interrupt program ...
Страница 513: ...13 PROGRAMMING 13 4 Program Example 511 13 Target position change program Absolute position restoration program ...
Страница 514: ...512 13 PROGRAMMING 13 4 Program Example Restart program Parameter data initialization program ...
Страница 515: ...13 PROGRAMMING 13 4 Program Example 513 13 Flash ROM write program Error reset program ...
Страница 516: ...514 13 PROGRAMMING 13 4 Program Example Stop program ...
Страница 565: ...APPENDICES Appendix 4 Operation Examples of When the Remote Head Module Is Mounted 563 A ...
Страница 568: ...566 APPENDICES Appendix 4 Operation Examples of When the Remote Head Module Is Mounted Common program ...
Страница 584: ...582 APPENDICES Appendix 4 Operation Examples of When the Remote Head Module Is Mounted Restart program ...
Страница 587: ...APPENDICES Appendix 4 Operation Examples of When the Remote Head Module Is Mounted 585 A Stop program ...
Страница 597: ......