![Mitsubishi Electric MELSEC iQ-R-R00CPU Скачать руководство пользователя страница 400](http://html.mh-extra.com/html/mitsubishi-electric/melsec-iq-r-r00cpu/melsec-iq-r-r00cpu_user-manual_239139400.webp)
398
24 DEVICE/LABEL INITIAL VALUE SETTINGS
24.1 Setting Initial Device/Label Values
24.1
Setting Initial Device/Label Values
This section describes the settings required to use initial device/label values.
Setting initial device values
This section describes the settings of initial device values.
Setting procedure
The procedure for using initial device values is as follows.
1.
First, the user must create an initial device value file. To set initial values to a local device, create an initial device value
file with the same name as the program which sets these values, and specify the range of the values. To set initial values
to a global device, create an initial device value file (with any name) which sets these initial values, and specify the range
of the values.
2.
On the device memory, set up initial device value data within the range specified in the initial device value file.
(
GX Works3 Operating Manual)
3.
In the "Device Memory Register Diversion", select the device memory which was set up in Step 2. Setting "Device
Memory Register Diversion" enables data set up on the device memory to be used as initial device values for the device
which is specified in the initial device value file.
(
GX Works3 Operating Manual)
4.
Configure CPU parameters. (
Page 398 Initial value setting)
5.
Write the set initial device value file and the CPU parameters to the CPU module.
(
GX Works3 Operating Manual)
6.
The data in the specified initial device value file is automatically set to the specified device or buffer memory of the
intelligent function module when the CPU module is powered off and on, reset, or the status changes from STOP to
RUN.
Initial value setting
Configure the initial value setting.
[CPU Parameter]
[File Setting]
[Initial Value Setting]
Window
Displayed items
*1 If noting is specified, initial global device values are not applied.
*2 It cannot be set in the R00CPU.
*3 If "Target Memory" is set to "Memory card", boot a target file from the SD memory card with the boot operation. (
*4 If "Setting of Device Initial Value Use Or Not" is set to "Use" and the specified initial global device value file does not exist, an error
occurs. If the other file (initial local device value file, initial global label value file, or initial local label value file) does not exist, an initial
value is not applied, but an error does not occur.
Item
Description
Setting range
Default
Target Memory
Sets the storage memory for the initial device value file, initial global label
value file, and initial local label value file.
• Data Memory
• Memory card
Data Memory
Setting of Device Initial
Value Use Or Not
Selects whether or not to use initial device values.
• Not Used
• Use
Not Used
Global Device Initial
Value File Name
Sets the name of the initial global device value file.
60 characters or less
Содержание MELSEC iQ-R-R00CPU
Страница 2: ......
Страница 151: ...9 MONITOR FUNCTION 9 1 Real Time Monitor Function 149 9 MEMO ...
Страница 323: ...18 SEQUENCE SCAN SYNCHRONIZATION SAMPLING FUNCTION 321 18 MEMO ...
Страница 330: ...328 20 ROUTING SETTING 20 3 Precautions MEMO ...
Страница 423: ...26 BASIC CONCEPT 26 8 State Transition of the Redundant System 421 26 MEMO ...
Страница 524: ...522 30 MAINTENANCE AND INSPECTION FOR A REDUNDANT SYSTEM 30 1 Module Replacement in the Redundant System MEMO ...
Страница 1009: ...APPX Appendix 14 List of Available SQL Commands for CPU Module Database Access Function 1007 A MEMO ...
Страница 1014: ...1012 APPX Appendix 15 Added and Enhanced Functions MEMO ...
Страница 1027: ......