13 DATABASE FUNCTION
13.3 CPU Module Database Access (from External Device) Function
Built-in database access setting
To use the CPU module database access function, set "To Use or Not to Use the Built-in Database Access" of the module
parameter to "Use" with the engineering tool.
[Navigation window]
[Parameter]
CPU module
[Module Parameter]
[Application Settings]
[Built-in Database
Access Setting]
Window
Displayed items
*1 Single-byte alphabetical characters and special characters (excluding " # % * + , / : ; < = > ? [ \ ] | ' { } & ~ $ @ ^) can be input.
*2 A space cannot be used as the first character.
Item
Description
Setting
range
Default
To Use or Not to Use the Built-in Database Access
Set whether to use the CPU module database access
function.
• Use
• Not Use
Not Use
Login Name
A user name to be used for the authentication at the
access to a database
1 to 31
characters
RCPU
Advanced
Settings
Password Setting
Current Password
A password to be used for the authentication at the
access to a database
0 to 31
characters
RCPU
New Password
A new password to be set
0 to 31
characters
Confirm New
Password
A password for confirmation. The password can be
changed only when this password matches a new
password.
0 to 31
characters
Built-in Database Access
Timer Setting
Message Monitoring
Timer
A monitoring timer for until the first message is sent
from the personal computer after the connection
establishment
1 to 16383s
5
Connection Monitoring
Timer
A monitoring timer for until the CPU module
disconnects the personal computer after the CPU
module recognizes that the personal computer stops
accessing to the CPU module
1 to 16383s
1800
Содержание MELSEC iQ-R-R00CPU
Страница 2: ......
Страница 151: ...9 MONITOR FUNCTION 9 1 Real Time Monitor Function 149 9 MEMO ...
Страница 323: ...18 SEQUENCE SCAN SYNCHRONIZATION SAMPLING FUNCTION 321 18 MEMO ...
Страница 330: ...328 20 ROUTING SETTING 20 3 Precautions MEMO ...
Страница 423: ...26 BASIC CONCEPT 26 8 State Transition of the Redundant System 421 26 MEMO ...
Страница 524: ...522 30 MAINTENANCE AND INSPECTION FOR A REDUNDANT SYSTEM 30 1 Module Replacement in the Redundant System MEMO ...
Страница 1009: ...APPX Appendix 14 List of Available SQL Commands for CPU Module Database Access Function 1007 A MEMO ...
Страница 1014: ...1012 APPX Appendix 15 Added and Enhanced Functions MEMO ...
Страница 1027: ......