background image

This manual confers no industrial property rights or any rights of any other kind, 
nor does it confer any patent licenses. Mitsubishi Electric Corporation cannot be 
held responsible for any problems involving industrial property rights which may 
occur as a result of using the contents noted in this manual.

Warranty

Exclusion of loss in opportunity and secondary loss from warranty liability
Regardless of the gratis warranty term, Mitsubishi shall not be liable for compensation to:
(1) Damages caused by any cause found not to be the responsibility of Mitsubishi.
(2) Loss in opportunity, lost profits incurred to the user by Failures of Mitsubishi products.
(3) Special damages and secondary damages whether foreseeable or not, compensation for 

accidents, and compensation for damages to products other than Mitsubishi products.

(4) Replacement by the user, maintenance of on-site equipment, start-up test run 

and other tasks.

For safe use

This product has been manufactured as a general-purpose part for general 
industries, and has not been designed or manufactured to be incorporated in 
a device or system used in purposes related to human life.
Before using the product for special purposes such as nuclear power, electric 
power, aerospace, medicine or passenger movement vehicles, consult with 
Mitsubishi Electric.
This product has been manufactured under strict quality control. However 
when installing the product where major accidents or losses could occur if the 
product fails, install appropriate backup or failsafe functions in the system.

HEAD OFFICE  : TOKYO BUILDING, 2-7-3 MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN

FX

3U

-485ADP-MB

Installation Manual

This manual describes the part names, dimensions, mounting, and specifications
of the product. Before use, read this manual and manuals of relevant products
fully to acquire proficiency in handling and operating the product. Make sure to
learn all the product information, safety information, and precautions.
And, store this manual in a safe place so that you can take it out and read it
whenever necessary. Always forward it to the end user.
Registration:
MODBUS

 is a registered trademark of Schneider Electric SA.

The company name and the product name to be described in this manual are the
registered trademarks or trademarks of each company.

Effective November 2016
Specifications are subject to change without notice.

©

 2007 Mitsubishi Electric Corporation

Manual Number

JY997D26301

Revision

G

Date

November 2016

Safety Precautions

 

(Read these precautions before use.)

This manual classify the safety precautions into two categories: 

 and 

.

Depending on circumstances, procedures indicated by 

 may also be

linked to serious results.
In any case, it is important to follow the directions for usage.

Associated Manuals

Indicates that incorrect handling may cause hazardous
conditions, resulting in death or severe injury.

Indicates that incorrect handling may cause hazardous
conditions, resulting in medium or slight personal injury
or physical damage.

Manual name

Manual No.

Description

FX

3S

 Series User’s Manual 

- Hardware Edition

JY997D48601

MODEL CODE: 

09R535

Explains FX

3S

 Series PLC

specification details for I/O,

w i r i n g ,   i n s t a l l a t i o n ,   a n d

maintenance.

FX

3G

 Series User’s Manual 

- Hardware Edition

JY997D31301

MODEL CODE: 

09R521

Explains FX

3G

 Series PLC

specification details for I/O,

w i r i n g ,   i n s t a l l a t i o n ,   a n d

maintenance.

FX

3GC

 Series User’s Manual

- Hardware Edition

JY997D45401

MODEL CODE:

09R533

Explains FX

3GC

 Series PLC

specification details for I/O,

w i r i n g ,   i n s t a l l a t i o n ,   a n d

maintenance.

FX

3U

 Series User’s Manual 

- Hardware Edition

JY997D16501

MODEL CODE: 

09R516

Explains FX

3U

 Series PLC

specification details for I/O,

w i r i n g ,   i n s t a l l a t i o n ,   a n d

maintenance.

FX

3UC

 Series User’s Manual 

- Hardware Edition

JY997D28701

MODEL CODE: 

09R519

Explains FX

3UC

 Series PLC

specification details for I/O,

w i r i n g ,   i n s t a l l a t i o n ,   a n d

maintenance.

FX

3S

/FX

3G

/FX

3GC

/FX

3U

/

FX

3UC

 Series Programming

Manual 
- Basic & Applied
 Instruction Edition

JY997D16601

MODEL CODE: 

09R517

Describes PLC programming

for basic/applied instructions

and devices.

FX Series User’s Manual 
- Data Communication
 Edition

JY997D16901

MODEL CODE: 

09R715

Describes N:N link, parallel

link, computer link, no protocol

c o m m u n i c a t i o n   b y   R S

instructions/FX

2N

-232IF.

How to obtain manuals

For the necessary product manuals or documents, consult with the Mitsubishi Electric
dealer from where you purchase your product.

Applicable standards

FX

3U

-485ADP-MB 

units made in April, 2007 or later comply with the EC Directive

(EMC Directive) and UL standards (UL, cUL). Further information can be found in the
following manual.

→ 

FX

3S

 Series Hardware Manual (Manual No. JY997D48301)

→ 

FX

3G

 Series Hardware Manual (Manual No. JY997D46001)

→ 

FX

3GC

 Series Hardware Manual (Manual No. JY997D45201)

→ 

FX

3U

 Series Hardware Manual (Manual No. JY997D50301)

→ 

FX

3UC

 (D, DS, DSS) Series Hardware Manual (Manual No. JY997D50501)

→ 

FX

3UC

-32MT-LT-2 Hardware Manual (Manual No. JY997D31601)

Regarding the standards that relate to the main unit, please refer to either the FX
series product catalog or consult with your nearest Mitsubishi product provider.

Attention

This product is designed for use in industrial applications.

1. Outline

The FX

3U

-485ADP-MB communication special adapter (hereinafter called 485ADP-MB)

is a special adapter for RS-485 communication with a terminal block (European type).
485ADP-MB is an isolated signal exchange unit of RS-485 serial data communication
between the PLC and RS-485 device.
The FX

3U

-485ADP-MB features all functionality that is available with the FX

3U

-

485ADP, except that it also has MODBUS communication available.

1.1 Communication Function

1.2 Incorporated Items

Verify that the following product and items are included in the package:

The label should be applied on the front of 485ADP-MB for checking station numbers in
N:N network, computer link, MODBUS communication, etc.

Manual name

Manual No.

Description

FX

3S

/FX

3G

/FX

3GC

/FX

3U

/

FX

3UC

 Series User’s Manual

- MODBUS Serial 
Communication Edition

JY997D26201

Explains the MODBUS serial

communication network.

Communication type

Function

N:N network

Data transfer between up to eight FX Series PLCs by the
simple program.

Parallel link

Data transfer between two FX Series PLCs specifying
master/slave station.

Computer link

Data transfer via dedicated protocol between PLC and
computer (specified as the master station).

Non-protocol 
communication

Serial communication via non-protocol between PLC and
RS-485 device.

Inverter 
communication

Controlling Mitsubishi's FREQROL inverter using inverter
communication instruction.

MODBUS 
communication

Data transfer for up to 32 slaves controlled by one master.

Product

FX

3U

-485ADP-MB communication special adapter

Accessories

Label for indication of link station number
Installation manual (This manual)

1.3 External Dimensions and Part Names 

1.4 Terminal Configuration

The terminal configuration of the RS-485 terminal on the 485ADP-MB is shown below.
Note that the terminal configuration is different from that of the FX

3U

-485-BD.

1.5 Terminal Resistor Selector Switch

485ADP-MB has a built-in terminal resistor.
A terminal resistor may be required depending on the communication type. Refer to the
following manual for the terminal resistor setting.

→ 

FX Series User's Manual - Data Communication Edition

→ 

FX

3S

/FX

3G

/FX

3GC

/FX

3U

/FX

3UC

 

Series User’s Manual

 - MODBUS Serial Communication Edition

[1] DIN rail mounting groove (DIN rail: DIN46277)
[2] Name plate
[3] Special adapter slide lock: 

Used to connect special adapter on left side of this special adapter.

[4] Special adapter connector cover:

Remove this cover for connecting special adapter on the left side.

[5] Direct mounting hole:2 holes of 

φ

4.5 (0.18") (mounting screw: M4 screw)

Not used when connecting to FX

3GC

/FX

3UC

 Series PLC.

[6] POWER LED (green): Lit while 5 V DC power is supplied from main unit.
[7] RD LED (red): 

Lit while receiving data from connected RS-485 device.

[8] SD LED (red): 

Lit while sending data to connected RS-485 device.

[9] Terminal resistor selector switch (330

Ω

/OPEN/110

Ω

)

[10] Special adapter connector:

Used to connect this special adapter to PLC main unit or special adapter.

[11] Terminal block (European type) for connecting RS-485 device

Use to connect RS-485 device to 485ADP-MB.

[12] DIN rail mounting hook
[13] Special adapter fixing hook
[14] Special adapter connector:

Used to connect communication special adapter or analog special adapter to
this adapter on left side.

Signal

name

Function

Signal direction

485ADP-MB

RS-485 

equipment

RDA(RXD+)

Receive data

RDB(RXD-)

SDA(TXD+)

Send data

SDB(TXD-)

SG(GND)

Signal ground

74(2.92")

[6]

[5]

[7]
[8]

[9]

[10]

[3]

[12]

[14]

[11]

Weight: Approx. 80 g (0.18 lbs)

Special adapter 

connector cover 

is removed  

7(0.28")

15.5

(0.65")

90(3.55")

98(3.86")

(mounting hole pitch)

106(4.18")

17.6
(0.7")

15.1
(0.6")

RDA
RDB
SDA
SDB
SG

[13]

[2]

[4]

[1]

Terminal screws

RDA

RDB

SDA

SDB

SG

330

Ω

OPEN

110

Ω

330

Ω

OPEN

110

Ω

330

Ω

OPEN

110

Ω

Setting terminal

resistor to 330

Ω

Setting no

terminal resistor

Setting terminal

resistor to 110

Ω

1.6 Operation of Terminal Resistor Selector Switch

Use the tip of tweezers, tip of mechanical pencil, minute screwdriver, or the tool
whose tip width is about 0.8 mm (0.03") when operating the terminal resistor
selector switch. 

Either 'push down' or 'push up' the switch to change the setting as indicated in
the figure above.
Confirm the clicking noise when setting the switch.

2. Channel Allocation

Up to two communication ports can be added to the main unit.
Refer to the following manual for equipment that occupies communication ports.

→ 

FX Series User’s Manual - Data Communication Edition

FX

3S 

Series PLC

Communication port channels are automatically allocated.

FX

3G

 Series PLC

Communication port channels are automatically allocated.

40-point, 60-point type

14-point, 24-point type

FX

3GC

 Series PLC

Communication port channels are automatically allocated. The communication
special adapter closer to the main unit is ch1.

FX

3U

/FX

3UC

-32MT-LT(-2) Series PLC

Communication port channels are automatically allocated. The communication
special adapter closer to the main unit is ch1.

Using one communication special a communication expansion board

330

Ω

OPEN

110

Ω

Pushing down

direction

Pushing up direction

Tool

Switch

330

Ω

OPEN

110

Ω

330

Ω

OPEN

110

Ω

Tool

Analog
special

adapter

     Main unit

(ch1)

FX

3S

-

CNV-ADP

FX

3U

-

485ADP

-MB

Main unit

(ch1)

Analog

special

adapter

Analog

special

adapter

(ch2)

FX

3G

-

CNV-ADP

FX

3U

-

485ADP

-MB

FX

3U

-

485ADP

-MB

Analog

special

adapter

adapter

Analog

special

FX

3U

-

485ADP

-MB

     Main unit

Communication

expansion board (ch2)

(ch1)

FX

3G

-

CNV-ADP

Analog

special

adapter

     Main unit

(ch1)

FX

3G

-

CNV-ADP

FX

3U

-

485ADP

-MB

Main unit

(ch1)

(ch2)

Analog

special

adapter

Analog

special

adapter

FX

3U

-

485ADP

-MB

FX

3U

-

485ADP

-MB

     Main unit

(ch2)

Communication 

expansion board (ch1)

Analog

special

adapter

Analog

special

adapter

Analog

special

adapter

Analog

special

adapter

FX

3U

-

485ADP

-MB

Using two communication special adapters

FX

3UC 

(D, DS, DSS) Series PLC

Communication port channels are automatically allocated. The communication
special adapter closer to the main unit is ch1.

3. Installation

For installation/uninstallation details, refer to the respective PLC User's manual
Hardware Edition.

3.1 Connection to the PLC

This section describes the connection method to the PLC (FX

3U

 Series PLC is

used for the following example).

For installation method to other PLCs, refer to the respective PLC User's manual
Hardware Edition.

Procedure

1) Turn off the power.

Disconnect all the cables connected to the PLC main unit and special adapter. 

Dismount the main unit and special adapter mounted on DIN rail or mounted

directly using screws. 

2) Install an expansion board to the main unit.

For installation of expansion board, refer to the following manual:

→ 

FX

3U

 Series User's Manual - Hardware Edition

3) Remove the special adapter connector cover

on the expansion board (Right fig.A).
In case of connecting this product to another
special adapter, please replace the
'expansion board' in the above description
with a 'special adapter' and perform the
procedure as indicated.

4) Slide the special adapter slide lock (Right

fig.B) of the main unit.
In case of connecting this product to another
special adapter, please replace the 'main
unit' in the above description with a 'special
adapter' and perform the procedure as
indicated. (Please replace the following
procedures similarly.)

INSTALLATION 
PRECAUTIONS

Make sure to cut off all phases of the power supply externally before
attempting installation or wiring work.
Failure to do so may cause electric shock or damage to the product.

INSTALLATION 
PRECAUTIONS

Use the product within the generic environment specifications described in
PLC main unit manual (Hardware Edition).
Never use the product in areas with excessive dust, oily smoke, conductive
dusts, corrosive gas (salt air, Cl

2

, H

2

S, SO

2

, or NO

2

), flammable gas,

vibration or impacts, or expose it to high temperature, condensation, or rain
and wind.
If the product is used in such conditions, electric shock, fire, malfunctions,
deterioration or damage may occur.

When drilling screw holes or wiring, make sure cutting or wire debris does not
enter the ventilation slits. 
Failure to do so may cause fire, equipment failures or malfunctions.

Do not touch the conductive parts of the product directly. 
Doing so may cause device failures or malfunctions.

Connect special adapter securely to their designated connectors.
Loose connections may cause malfunctions.

Analog

special

adapter

Analog

special

adapter

Analog

special

adapter

Analog

special

adapter

FX

3U

-

485ADP

-MB

FX

3U

-

485ADP

-MB

     Main unit

FX

3U

-CNV-BD

(ch1)

(ch2)

Analog

special

adapter

Analog

special

adapter

Analog

special

adapter

Analog

special

adapter

FX

3U

-

485ADP

-MB

FX

3U

-

485ADP

-MB

    Main unit

(ch1)

(ch2)

RUN

STOP

FX

FX

3U

3U

-48MR/ES

-48

MR

/ES

FX

3U-48M

3)

4)

B

B

A

4)

5) Connect the special 

adapter (Right fig.C) 
to the main unit as 
shown on the right.

6) Slide back the 

special adapter slide
lock (Right fig.B) of 
the main unit to fix the 
special adapter (Right 
fig.C). 

Connection precautions

Connect all the high-speed I/O special adapters before connecting other special
adapters when they are used in combination.

Do not connect a high-speed I/O special adapter on the left side of a
communication or analog special adapter.

4. Wiring

For wiring details, refer to the following manual.

→ 

FX Series User's Manual - Data Communication Edition

→ 

FX

3S

/FX

3G

/FX

3GC

/FX

3U

/FX

3UC

 Series User’s Manual

- MODBUS Serial Communication Edition

Wiring precaution

Do not attach the terminal block (replacement European terminal block) for

connecting RS-485 device which is already wired to FX

3U

-485-BD.

If attached as its left and right are confused, the terminal configuration becomes

upside down and no communication is performed.

5. Specification 

WIRING 
PRECAUTIONS

Make sure to cut off all phases of the power supply externally before attempting
installation or wiring work.
Failure to do so may cause electric shock or damage to the product.

WIRING 
PRECAUTIONS

When drilling screw holes or wiring, make sure cutting or wire debris does not
enter the ventilation slits. 
Failure to do so may cause fire, equipment failures or malfunctions.

Make sure to observe the following precautions in order to prevent any damage to
the machinery or accidents due to abnormal data written to the PLC under the
influence of noise:

1) Do not bundle the main circuit line together with or lay it close to the main

circuit, high-voltage line or load line. 
Otherwise, noise disturbance and/or surge induction are likely to take place. As
a guideline, lay the control line at least 100mm (3.94") or more away from the
main circuit or high-voltage lines.

2) Ground the shield wire or shield of the shielded cable at one point on the PLC.

However, do not use common grounding with heavy electrical systems.

Make sure to properly wire to the terminal block (European type) in accordance
with the following precautions. 
Failure to do so may cause electric shock, equipment failures, a short-circuit, wire
breakage, malfunctions, or damage to the product.

- The disposal size of the cable end should follow the dimensions described in

the manual of the PLC main unit.

- Tightening torque should follow the specifications in the manual of the PLC 

main unit.

- Twist the end of strand wire and make sure that there are no loose wires.
- Do not solder-plate the electric wire ends.
- Do not connect more than the specified number of wires or electric wires of 

unspecified size.

- Affix the electric wires so that neither the terminal block nor the connected 

parts are directly stressed.

STARTUP AND 
MAINTENANCE 
PRECAUTIONS

Do not disassemble or modify the unit. 
Doing so may cause fire, equipment failures, or malfunctions. 
* For repair, contact your local Mitsubishi Electric representative.

Do not drop the product or exert strong impact to it.
Doing so may cause damage.

DISPOSAL 
PRECAUTIONS

Please contact a certified electronic waste disposal company for the
environmentally safe recycling and disposal of your device.

RUN

STOP

FX

FX

3U

3U

-48MR/ES

-48

MR

/ES

FX

FX

3U

3U

-48M

-48M

POWER

RD

SD

FX

3U-485ADP

-MB

FX

3U-48M

6)

C

B

B

5)

5)

5)

6)

5.1 Applicable PLC

The version number can be checked by monitoring D8001/D8101, as well the last three
digits indicate the version number.

5.2 General Specifications

Items other than the following are equivalent to the those of the PLC main unit.
For general specifications, refer to the respective PLC User's manual Hardware Edition.

5.3 Power Supply Specification

5.4 Performance Specification

*1 Applicable for FX

3U

/FX

3UC

 Series PLC Ver. 2.41 or later and FX

3S

/FX

3G

/FX

3GC

Series PLC.

*2 When you set the baud rate to 38400 bps or more in a FX

3S

/FX

3G

/FX

3GC

 Series

PLC, please set D8411 (D8431) to be 3 ms or more. When D8411 (D8431) is set
at less than 3 ms, it may not be able to communicate normally.

TRANSPORTATION AND
STORAGE PRECAUTIONS

The product is a precision instrument. During transportation, avoid impacts larger
than those specified in the general specifications by using dedicated packaging
boxes and shock-absorbing palettes. Failure to do so may cause failures in the
product. After transportation, verify operation of the product and check for damage
of the mounting part, etc.

Model name

Applicability

FX

3S

 Series PLC

Ver. 1.00 or later for all communication functions

FX

3G

 Series PLC

Ver. 1.30 or later for MODBUS communication
Ver. 1.10 or later for inverter communication
Ver. 1.00 or later for all communication functions except 
MODBUS and inverter

FX

3GC

 Series PLC Ver. 1.40 or later for all communication functions

FX

3U

 Series PLC

Ver. 2.40 or later for MODBUS communication
Ver. 2.20 or later for all communication functions except MODBUS

FX

3UC

 Series PLC

Ver. 2.40 or later for MODBUS communication
Ver. 1.00 or later for all communication functions except MODBUS

Item

Specification

Dielectric 
withstand voltage

500 V AC, one minute

Between all external 
terminals and ground 
terminal of PLC main unit

Insulation 
resistance

5 M

Ω

  o r   hi g h e r  b y   5 0 0  V   D C

insulation resistance tester

Item

Specification

Current 
consumption

20 mA
5 V DC power is supplied from the internal power supply of main
unit.

Item

Specification

Transmission 
standard

Conforming to RS-485/RS-422

Type of isolation

Photocoupler isolation

Transmission 
distance

Total extension distance: 500 m (1640' 5") or less
[50 m (164' 0") or less if FX

1N

-485-BD, FX

2N

-485-BD or

FX

3U

-485-BD is installed to connected equipment]

Connection method

European type terminal block, AWG 22-20 (when inserting
one twisted pair cable), AWG 22 (when inserting two twisted
pair cables)
Tightening torque: 0.22 to 0.25 N

m

Number of occupied 
I/O points

0 point (This number is not related to the maximum number of
input/output points of the PLC.) 

Communication 
method

Half-duplex

Baud rate

N:N network: 38400 bps
Parallel link: 115200 bps
Computer link, Non-protocol communication: 

300/600/1200/2400/4800/9600/19200/38400

*1

 bps

Inverter communication:

4800/9600/19200/38400

*1

 bps

MODBUS communication

*2

:

300/600/1200/2400/4800/9600/19200/38400

*3

/57600

*3

/

115200

*3

 bps

Number of Slaves
(MODBUS)

16 Slaves, 32 Slaves

*3

Communication 
format

N:N network, Parallel link, 
Computer link (dedicated protocol: format 1/format 4), 
Non-protocol, Inverter, and MODBUS communication

LED display: 
LED color

Power: green, RD: red, SD: red

*3 Applicable for products manufactured in July, 2012 or later (manufacturer's

serial number: 127**** or later). The year and month of production of the
special adapter can be checked from the manufacturer's serial number "S/
N" indicated on the label.
For manufacturer's serial number, refer to the following manual.

→ 

FX

3S

/FX

3G

/FX

3GC

/FX

3U

/FX

3UC

 Series User’s Manual

- MODBUS Serial Communication Edition

6. 「电器电子产品有害物质限制使用标识要求」的表示方式

Note: This symbol mark is for China only.

含有有害6物质的名称,含有量,含有部品

本产品中所含有的有害 6 物质的名称,含有量,含有部品如下表
所示。

产品中有害物质的名称及含量

本表格依据SJ/T 11364的规定编制。

○:表示该有害物质在该部件所有均质材料中的含量均在GB/T

26572规定的限量要求以下。

×:表示该有害物质至少在该部件的某一均质材料中的含量超出GB/T

26572规定的限量要求。

部件名称

有害物质

(Pb)

(Hg)

(Cd)

六价铬

(Cr(VI))

多溴联苯

(PBB)

多溴

二苯醚
(PBDE)

可编程
控制器

外壳

印刷基板

×

Side

A

Side

B

JAPANESE

ENGLISH

JY997D26301G

Side

B

Отзывы: