![Mitsubishi Electric MELIPC MI5000 Series Скачать руководство пользователя страница 93](http://html.mh-extra.com/html/mitsubishi-electric/melipc-mi5000-series/melipc-mi5000-series_user-manual_239727093.webp)
7 CC-Link IE Field Network Basic FUNCTION
7.3 CC-Link IE Field Network Basic diagnostics
91
7
Displayed items
*1 The maximum and minimum values of the link scan time indicate the maximum and minimum values from the time the power supply of
this product was turned ON until it was turned OFF. When the transmission cycle was changed by a C Controller dedicated function
(CCPU_ChangeCCIEFBCycPrm) during cyclic transmission, the maximum and minimum values of the link scan time are reset.
*2 When the transmission status is unconfirmed, potential causes are as follows: a slave station configured by parameters has not started,
the cable between a master station and slave station is disconnected, or the IP address or subnet mask of the master station/slave
station is configured incorrectly.
*3 When the count exceeds 65,535, counting continues from 1.
*4 Clear after dealing with the errors of slave stations.
Item
Description
Total Slave Stations (Parameter)
Displays the number of slave stations set in parameters.
IP Address
Displays the IP address of the master station. Switch between decimal and hexadecimal display with "Switch
IP address display".
Error Code
Displays master station error codes.
[Error Details] button
Displays details of occurring errors, and of handling methods.
Link Scan Time/Error Stations
The link scan time (current, maximum, minimum)
of each group and the number of error stations and
number of unconfirmed stations are displayed.
The following items show the status of error stations and unconfirmed stations.
• Error Stns: station at which an error is occurring
• Unfixed Stns: station with an unconfirmed transmission status (not including reserved stations)
Diagnostics Target Group
Select a group displayed in the list of diagnosis information.
Station No.
Displays the station No. of the slave station.
Occpd Stns
Displays the exclusive station number set in parameters.
Reserved Station
Displays the reserved station set in parameters.
IP Address
Displays the IP address set in parameters.
If An IP address is not set in the reserved station, then "
" will be displayed.
Transmission Status
Station transmission status.
• Unfixed: Transmission with a master station unfixed
• Transmitting: In cyclic transmission
• Disconnecting: Disconnected from master station
Disconnections
Displays the accumulated number of disconnections that were detected.
• 0: No disconnections
• 1 to 65535: Number of disconnection detections (accumulated number)
Time-out Count
Displays the accumulated number of timeouts that occurred.
• 0: No timeouts
• 1 to 65535: Number of timeouts (accumulated number)
The Latest Error
Displays the latest error code of the slave station. The latest error remains the same even with a change
from slave station disconnection (error occurring) to reconnection. The error is updated (overwritten) when a
new separate error occurs.
Detailed errors of slave stations cannot be confirmed by CC-Link IE Field Network Basic diagnosis. For
errors that occur at slave stations, check the value stored in ’Diagnostic information 2’ (Un\G1068 to
Un\G1077).
Error Details...
Displays details of occurring errors, and of handling methods.
[Clear Latest Error Code] button
Clears the error code.
Only those buttons on the monitor can be clicked.
Содержание MELIPC MI5000 Series
Страница 1: ...MELIPC MI5000 Series User s Manual Application MI5122 VW ...
Страница 2: ......
Страница 18: ...16 MEMO ...
Страница 22: ...20 1 DIAGNOSTIC AND MAINTENANCE FUNCTIONS 1 1 Watchdog Timer WDT Function MEMO ...
Страница 42: ...40 5 iQSS FUNCTION MEMO ...
Страница 146: ...144 11 SECURITY FUNCTION 11 3 IP Filter Function MEMO ...
Страница 148: ...146 12 MELSOFT PRODUCT AND GOT CONNECTION FUNCTION 12 1 Connection Method MEMO ...
Страница 150: ...148 13 SYSTEM COUNT FUNCTION MEMO ...
Страница 152: ...150 14 TIMER EVENT FUNCTION MEMO ...
Страница 160: ...158 15 OS LINKING FUNCTIONS 15 3 Inter OS Event Notification Function MEMO ...
Страница 162: ...160 16 SERIAL INTERFACE SWITCHING FUNCTION MEMO ...
Страница 165: ...17 BASIC PARAMETERS 17 1 Basic Parameter List 163 17 Operation related setting Window ...
Страница 170: ...168 17 BASIC PARAMETERS 17 1 Basic Parameter List RAS setting Window ...
Страница 174: ...172 17 BASIC PARAMETERS 17 1 Basic Parameter List External device connection settings Window ...
Страница 177: ...17 BASIC PARAMETERS 17 1 Basic Parameter List 175 17 External device connection applicable settings Window ...
Страница 313: ...APPX Appendix 10 List of VxWorks Components 311 A MEMO ...
Страница 315: ...I 313 MEMO ...
Страница 319: ......