Chapter 9 Setup
9–7
(7) Power supply type (SV036: PTYP)
Name Abbrev.
Details
Setting range
(unit)
SV036 PTYP
Power supply type
HEX setting
Refer to the following table and set SV036: PTYP ptyp.
No.
0xKw
0x
1xKw
1x
2xKw
2x
3xKw
3x
4xKw
4x
5xKw
5x
6x 7x
0xKw
8x
0
PS not
connected
CV-300
1
CV-110
CR-10
2
CV-220
CR-15
3
CR-22
4
CV-37
CR-37
5 CV-150
CV-450
CV-550
6
CV-55 CV-260
CR-55
7
CV-370
8
CV-75
CR-75
9
CV-185
CR-90
A
B
C
D
E
F
List of regenerative resistor types
Refer to the following table and set SV036: PTYP port. (For MDS-A-CR unit)
No.
Regenerative resistor
type
Resistance
value (
Ω
)
Wattage (W)
0
1 GZG200W260HMJ
26
80
2 GZG300W130HMJ×2
26
150
3 MR-RB30
13 300
4 MR-RB50
13 500
5 GZG200W200HMJ×3
6.7
350
6 GZG300W200HMJ×3
6.7
500
7 R-UNIT-1
30 700
8 R-UNIT-2
15 700
9 R-UNIT-3
15 2100
A
B
C
D
E
F
F E D C B A 9 8 7 6 5 4 3 2 1 0
amp rtyp
ptyp
bit Name
Details
0
1
2
3
4
5
6
7
ptyp
Set the power supply type.
8
9
A
B
rtyp
Set 0 if the power supply unit is a power regeneration type.
If the power supply unit is a resistance regeneration type, set the type of resistor
being used.
C
D
E
F
amp
Set the driver model No.
0: MDS-B-V14/V24, V14L, MDS-B-V1/V2/SP, MDS-A-V1/V2/SP
1: MDS-A-SVJ
2: MDS-A-SPJ