Safety Precautions

Mitsubishi Electric, MA00776

1-1

1

Safety Precautions

Both the installer and the owner and/or operator of the operator terminal must read 
and understand this installation manual.

1.1 UL Installation

Power, input and output (I/O) wiring must be in accordance with Class 1, Division 
2 wiring methods (Article 501-4 (b) of the National Electric Code, NFPA 70) and 
in accordance with the authority having jurisdiction.

1.2 General

– Only qualified personnel may install or operate the operator terminal.

– The operator terminal must be installed according to the installation instructions.

– The operator terminal is designed for stationary installation on a plane surface, 

where the following conditions are fulfilled:

• no high explosive risks
• no  strong  magnetic  fields
• no  direct  sunlight
• no large, sudden temperature changes

– Never allow fluids, metal filings or wiring debris to enter any openings in the 

operator terminal. This may cause fire or electrical shock.

– The operator terminal fulfills the requirements of article 4 of EMC directive 

89/336/EEC.

– Storing the operator terminal where the temperature is lower/higher than 

recommended in this manual can cause the LCD display liquid to congeal/become 
isotopic.

– The LCD display liquid contains a powerful irritant. In case of skin contact, wash 

immediately with plenty of water. In case of eye contact, hold the eye open, flush 
with plenty of water and get medical attention.

– The supplier is not responsible for modified, altered or reconstructed equipment.

– Use only parts and accessories manufactured according to specifications of the 

supplier.

– Peripheral equipment must be appropriate for the application and location.

– The figures in this manual serves an illustrative purpose. Because of the many 

variables associated with any particular installation, the supplier cannot assume 
responsibility for actual use based on the figures.

– The supplier neither guarantees that the operator terminal is suitable for your 

particular application, nor assumes responsibility for your product design, 
installation or operation.

1.3 During Use

– Keep the operator terminal clean.

– Emergency stop and other safety functions may not be controlled from the 

operator terminal.

– Do not use too much force or sharp objects when touching the keys, display etc.

Содержание Mac E Series

Страница 1: ...Mac E Series Human Machine Interface Installation Manual E1070 INDUSTRIAL AUTOMATION MITSUBISHI ELECTRIC MITSUBISHI ELECTRIC Art no 169276 10 02 2006 Version A ...

Страница 2: ......

Страница 3: ...rinting The manufacturer reserves the right to change any information without updating this publication The manufacturer assumes no responsibility for any errors that may appear in this document Read the entire installation manual prior to installing and using this equipment Only qualified personnel may install operate or repair this equipment The manufacturer is not responsible for modified alter...

Страница 4: ...Foreword Mitsubishi Electric MA00776 ...

Страница 5: ...tion 2 1 2 1 Space Requirements 2 1 2 2 Installation Process 2 1 2 2 1 Mode Switches 2 3 2 2 2 Connections to the Controller 2 3 2 2 3 Other Connections and Peripherals 2 3 3 Technical Data 3 1 4 Chemical Resistance 4 1 4 1 Metal Casing 4 1 4 2 Keyboard and Display 4 1 4 2 1 Autotex F157 4 1 4 2 2 Display Surface 4 2 5 Operator Terminal Drawings 5 1 5 1 Communication Ports 5 1 5 2 E1070 Outline 5 ...

Страница 6: ...Table of Contents Mitsubishi Electric MA00776 ...

Страница 7: ...ive 89 336 EEC Storing the operator terminal where the temperature is lower higher than recommended in this manual can cause the LCD display liquid to congeal become isotopic The LCD display liquid contains a powerful irritant In case of skin contact wash immediately with plenty of water In case of eye contact hold the eye open flush with plenty of water and get medical attention The supplier is n...

Страница 8: ... supply Clean the display and surrounding front cover with a soft cloth and mild detergent Replacing the battery incorrectly may result in explosion Only use batteries recommended by the supplier 1 5 Dismantling and Scrapping The operator terminal or parts thereof shall be recycled according to local regulations The following components contain substances that might be hazardous to health and the ...

Страница 9: ...er Note Place the operator terminal on a stable surface during installation Dropping it or letting it fall may cause damage 2 Place the panel cut out where the operator terminal is to be situated draw along the outer sides of the holes and cut according to the markings If access to the text strip is needed add extra space in the lower left corner 50 mm 50 mm 100 mm 285 mm 177 mm 56 mm 100 mm 100 m...

Страница 10: ...6 0 5 1 0 Nm B C D A Caution Ensure that the operator terminal and the controller system have the same electrical grounding reference voltage level otherwise errors in communication may occur Caution Use only shielded communication cables Separate high voltage cables from signal and supply cables Caution The operator terminal must be brought to ambient temperature before it is started up If conden...

Страница 11: ...erator terminal to the controller please refer to the help file for the driver in question 2 2 3 Other Connections and Peripherals Cables peripheral equipment and accessories must be suitable for the application and its environment For further details or recommendations please refer to the supplier Caution When using a compact flash card do not remove the card when the busy indicator is illuminate...

Страница 12: ...Installation 2 4 Mitsubishi Electric MA00776 ...

Страница 13: ...inimum life of the real time clock battery 3 years Temperature coefficient 0 004 ppm C2 Power consumption at rated voltage Normal 0 4 A Maximum 0 9 A Display TFT LCD 640 x 480 pixels 64K color CCFL backlight lifetime at the ambient temperature of 25 C 50 000 h Active area of display W x H 131 5 x 98 6 mm Fuse Internal DC fuse 3 15 AT 5 x 20 mm Power supply 24V DC 20 30V DC 3 pin jack connection bl...

Страница 14: ...Technical Data 3 2 Mitsubishi Electric MA00776 ...

Страница 15: ...c acid 10 Urea saturated FAM Normal petrol Sodium di chromate saturated Hydroperoxide 3 Alcohol 95 Caustic soda 5 Acetic acid 10 Phosphoric acid 43 Sodium hypochlorite solution Alu cleaner Glycol Sodium carbonate 10 Industrial petrol Sodium chloride 20 Potassium ferrocyanide ferricyanide Sodium hypchlorite 20 bleach 1 1 1 Trichloroethane Genklene Cyclohexanol Acetaldehyde Ethylacetate Diacetone al...

Страница 16: ...ble change Ammonia 40 Linseed oil Dioctyl Phthalate Caustic soda 40 Paraffin oil Sodium carbonate Hydrogen peroxide 25 Blown castor oil Petrol Alkalicarbonate Silicone oil Teepol Bichromate Turpentine substitute Water Diesel oil Univeral brake fluid Sea water Acetonitrile Decon Sodium bisulphate Aviation fuel Concentrated mineral acids Benzyl alcohol Concentrated caustic solution Mehylene chloride...

Страница 17: ... Electric MA00776 4 3 Carbon tetrachloride Hydrogen peroxide 28 Sodium hypochlorite 10 Caustic soda 48 Isopropyl alcohol Sulfuric acid specific gravity 1 84 Citric acid Kerosene Sulfuric acid 30 Cotton seed oil Methy alcohol Toluene ...

Страница 18: ...Chemical Resistance 4 4 Mitsubishi Electric MA00776 ...

Страница 19: ...Operator Terminal Drawings Mitsubishi Electric MA00776 5 1 5 Operator Terminal Drawings 5 1 Communication Ports Drawing No 5005S Date 2004 10 27 RS 232 RS 422 RS 422 485 RS 485 Ethernet USB ...

Страница 20: ...Operator Terminal Drawings 5 2 Mitsubishi Electric MA00776 5 2 E1070 Outline Drawing No 5031S Date 2004 10 14 ...

Страница 21: ...Operator Terminal Drawings Mitsubishi Electric MA00776 5 3 5 3 E1070 Text Strip Drawing No 5027S Date 2004 08 12 ...

Страница 22: ...Operator Terminal Drawings 5 4 Mitsubishi Electric MA00776 ...

Страница 23: ......

Страница 24: ...a Voda 36 1 81 MD 2061 Chisinau Phone 373 0 2 562 263 Fax 373 0 2 562 263 e mail intehsis mdl net Koning Hartman B V NETHERLANDS Donauweg 2 B NL 1000 AK Amsterdam Phone 31 0 20 587 76 00 Fax 31 0 20 587 76 05 e mail info koningenhartman com Beijer Electronics A S NORWAY Teglverksveien 1 N 3002 Drammen Phone 47 0 32 24 30 00 Fax 47 0 32 84 85 77 e mail info beijer no MPL Technology Sp z o o POLAND ...

Отзывы: