MODEL: HD-6000
Page 13
A. A/V Memory
Each of the external inputs has its own Audio/Video Memory. A change in an A/V setting at a specific input is
stored in memory for that specific input.
B. A/V Reset
1. Press the GUIDE and FORMAT buttons on the front panel to reset all A/V Memories to default.
2. The AV Reset in the user’s menu initializes only the selected input’s A/V Memory.
LED Indicator Diagnostics
The “POWER/TIMER” LED provides an indication of the sets operation, and the possible cause of a malfunction.
1. Initial Control Circuitry Check
Immediately after the TV is connected to an AC power source:
2. Error Code Operational Check
Note:
The Set Top Box must be in “Shut Down” and not have been switched Off, to perform the Error Code
Operational Check. When the unit is switched Off, the code automatically resets to “12” No Error.
Pressing the front panel “DEVICE” and “MENU” buttons at the same time, and holding for 5 seconds,
activates the Error Code Mode. The LED flashes denoting a two digit Error Code, or indicating no problem
has occured since the last Initalization.
Note:
The front panel buttons must be used, NOT those on the Remote Control.
•
The number of flashes indicates the value of the MSD (tens digit) of the Error Code.
•
The flashing then pauses for approximately 1/2 second.
•
The LED then flashes indicating the value of the LSD (ones digit) of the Error Code.
•
The Error Code is repeated a total of 5 times.
Example: If the Error Code is “35”, the LED will flash three times, pause, and then flash five times.
4. Error Codes
The Error Code designations indicating malfunction, or no malfunction, are listed below:
Remote Control Operational Modes
There are two Remote Hand Unit Operational Modes, “Standard” and “NetCommand
TM
”. The Remote is initially
in the “Standard” mode. The “NetCommand
T
” mode is used when controlling Home Theater devices using
NetCommand. To change the Remote Operational Mode:
•
Set the Remote to the CABLE/DBS/DTV Layer.
•
Point the Remote away from the STB.
•
To change to “Netcommand” ... Hold the “Power” button and press “1-9-7” in sequence.
•
To change to “Standard” ... Hold the “Power” button and press “0-0-0” in sequence.
LED Indications
Conditions
Probable Cause
Off
After AC is applied
Standby Power Supply or TV µPC not running
Fast Bllink for 70 sec.
After AC is applied
Normal DM µPC is booting up
Fast Blink (doesn't stop)
After AC is applied
DM µPC failed to boot up
Slow Blink
Set in Off
Normal - Timer is set for Automatic Turn ON
Error Code
Probable Cause
12
Normal Operation - No Error Detected
35
Fan Stopped
41
Short Detected
Содержание HD-6000
Страница 2: ......
Страница 7: ...MODELS HD 6000 Page 7 PWB LOCATIONS Disassembly Sequence ...
Страница 8: ...Page 8 MODELS HD 6000 TOP COVER REMOVAL ...
Страница 10: ...Page 10 MODELS HD 6000 PWB Removal ...
Страница 29: ...MODEL HD 6000 Page 29 Standby Supplies ...
Страница 30: ...MODEL HD 6000 Page 30 PWB DM Power Supplies PWB SIGNAL Switched Supplies ...
Страница 31: ...MODEL HD 6000 Page 31 VIDEO SELECT CIRCUITRY ...
Страница 32: ...MODEL HD 6000 Page 32 VIDEO OUTPUT CIRCUITRY ...
Страница 33: ...MODEL HD 6000 Page 33 SYNC SIGNAL SELECTION ...
Страница 34: ...MODEL HD 6000 Page 34 Sync Output Path Record Signal Path ...
Страница 35: ...MODEL HD 6000 Page 35 Sound Signal Path ...
Страница 36: ...MODEL HD 6000 Page 36 CONTROL CIRCUITRY ...
Страница 37: ...MODEL HD 6000 Page 37 COMMAND INPUT CIRCUITRY MACROVISION DETECTION ...
Страница 38: ...MODEL HD 6000 Page 38 DM Signal Path ...
Страница 40: ......