MODEL: HD-4001
Page 15
A. A/V Memory
Each of the external inputs has its’ own Audio/Video Memory. A change in an A/V setting at a specific input is
stored in memory for that specific input.
B. A/V Reset
The AV Reset in the user’s menu initializes only the selected input’s A/V Memory.
LED Indicator Diagnostics
The “POWER/TIMER” LED provides an indication of the sets operation, and the possible cause of a malfunction.
1. Initial Control Circuitry Check
Immediately after the TV is connected to an AC power source:
2. Error Code Operational Check
Note:
The Set Top Box must be in “Shut Down” and not have been switched Off, to perform the Error Code
Operational Check. When the unit is switched Off, the code automatically resets to “12” No Error.
Pressing the front panel “DEVICE” and “MENU” buttons at the same time, and holding for 5 seconds,
activates the Error Code Mode. The LED flashes denoting a two digit Error Code, or indicating no problem
has occured since the last Initalization.
Note:
The front panel buttons must be used, NOT those on the Remote Control.
•
The number of flashes indicates the value of the MSD (tens digit) of the Error Code.
•
The flashing then pauses for approximately 1/2 second.
•
The LED then flashes indicating the value of the LSD (ones digit) of the Error Code.
•
The Error Code is repeated a total of 5 times.
Example: If the Error Code is “23”, the LED will flash two times, pause, and then flash three times.
4. Error Codes
The Error Code designations indicating malfunction, or no malfunction, are listed below:
Remote Control Operational Modes
There are two Remote Hand Unit Operational Modes, “Standard” and “NetCommand
TM
”. The Remote is initially
in the “Standard” mode. The “NetCommand
TM
” mode is used when controlling Home Theater devices using
NetCommand
TM
. To change the Remote Operational Mode:
•
Set the Remote to the CABLE/DBS/DTV Layer.
•
Point the Remote away from the STB.
•
To change to “Netcommand
TM
” ... Hold the “Power” button and press “1-9-7” in sequence.
LED Indications
Conditions
Probable Cause
Off
After AC is applied
Standby Power Supply or TV µPC not running
Fast Bllink for 70 sec.
After AC is applied
Normal DM µPC is booting up
Fast Blink (doesn't stop)
After AC is applied
DM µPC failed to boot up
Slow Blink
Set in Off
Normal - Timer is set for Automatic Turn ON
Error Code
Probable Cause
12
Normal Operation - No Error Detected
35
Fan Stopped
41
Short Detected
Содержание HD-4001
Страница 2: ......
Страница 8: ...Page 8 MODELS HD 4001 DISASSEMBLY TOP COVER REMOVAL Top Cover ...
Страница 10: ...Page 10 MODELS HD 4001 SIGNAL BRACKET REMOVAL SIGNAL BRACKET PWB Support Post FAN ...
Страница 11: ...MODELS HD 4001 Page 11 REAR PANEL REMOVAL FAN PWB ...
Страница 31: ...MODEL HD 4001 Page 31 Standby Supplies ...
Страница 32: ...MODEL HD 4001 Page 32 PWB DM Power Supplies PWB SIGNAL Switched Supplies ...
Страница 33: ...MODEL HD 4001 Page 33 Tuners Analog Video Select Circuitry ...
Страница 34: ...MODEL HD 4001 Page 34 Digital Video Signal Path ...
Страница 35: ...MODEL HD 4001 Page 35 Sync Signal Selection Sync Output Path ...
Страница 36: ...MODEL HD 4001 Page 36 Sound Signal Path ...
Страница 37: ...MODEL HD 4001 Page 37 Control Circuitry ...
Страница 38: ...MODEL HD 4001 Page 38 Command Input Circuitry Macrovision Detection ...