19 - 10
19. ENERGY MEASURING UNIT/ELECTRIC MULTI-MEASURING INSTRUMENT CONNECTION
19.5 Setting of Energy Measuring Unit/Electric Multi-measuring Instrument
19.5 Setting of Energy Measuring Unit/
Electric Multi-measuring Instrument
POINT
POINT
POINT
Energy measuring unit/electric multi-measuring
instrument
For details of the energy measuring unit/electronic
multi-measuring instrument, refer to the following
manual.
Energy measuring unit/Electronic multi-
measuring instrument User's Manual
19.5.1 Connecting to an energy
measuring unit/electronic
multi-measuring instrument
Communication settings
Make the communication settings with the front
operation switch on the energy measuring unit/
electronic multi-measuring instrument.
*1
Indicates only the transmission speeds that can be set on
the GOT side.
*2
Adjust the settings with GOT settings.
19.5.2 Station number setting
In the MODBUS network, a maximum of 31 energy
measuring units/electronic multi-measuring instruments
can be connected to 1 GOT.
Assign a non-overlapped station number ranging from 1 to
247 arbitrarily to each energy measuring unit/electronic
multi-measuring instrument.
In the system configuration, the energy measuring unit/
electric multi-measuring instrument with the station number
set with the host address must be included. The station
number can be set without regard to the cable connection
order. There is no problem even if station numbers are not
consecutive.
Series
Model name
Refer to
Energy measuring unit
EMU4-BD1-MB
EMU4-HD1-MB
Electric multi-measuring instrument
ME110SSR-MB
ME96NSR-MB
Item
Set value
Transmission speed
*1*2
9600bps, 19200bps, 38400bps
Data Bit
8bits (Fixed)
Stop Bit
*2
1bit, 2bits
(Default: 1bit)
Parity
*2
NONE/EVEN/ODD
(Default: EVEN)
Device address
*2
1 to 247
(Default: 1)
Examples of station number setting
Station
No.3
Station
No.15
Station
No.1
GOT
Содержание GT15
Страница 2: ......
Страница 34: ...A 32 ...
Страница 92: ......
Страница 110: ...2 18 2 DEVICE RANGE THAT CAN BE SET 2 9 MELSEC WS ...
Страница 134: ...3 24 3 ACCESS RANGE FOR MONITORING 3 7 Connection to the Head Module of CC Link IE Field Network System ...
Страница 186: ...5 10 5 BUS CONNECTION 5 2 System Configuration ...
Страница 218: ...5 42 5 BUS CONNECTION 5 4 Precautions ...
Страница 254: ...6 36 6 DIRECT CONNECTION TO CPU 6 6 Precautions ...
Страница 286: ...7 32 7 COMPUTER LINK CONNECTION 7 6 Precautions ...
Страница 350: ...8 64 8 ETHERNET CONNECTION 8 5 Precautions ...
Страница 368: ...9 18 9 MELSECNET H CONNECTION PLC TO PLC NETWORK 9 5 Precautions ...
Страница 420: ...11 26 11 CC Link IE CONTROLLER NETWORK CONNECTION 11 5 Precautions ...
Страница 440: ...12 20 12 CC Link IE FIELD NETWORK CONNECTION 12 5 Precautions ...
Страница 490: ...13 50 13 CC Link CONNECTION INTELLIGENT DEVICE STATION 13 5 Precautions ...
Страница 510: ......
Страница 564: ...15 54 15 INVERTER CONNECTION 15 7 Precautions ...
Страница 668: ......
Страница 712: ...21 12 21 MULTIPLE GT14 GT12 GT11 GT10 CONNECTION FUNCTION 21 5 Precautions ...
Страница 713: ...MULTI CHANNEL FUNCTION 22 MULTI CHANNEL FUNCTION 22 1 ...
Страница 714: ......
Страница 760: ...22 46 22 MULTI CHANNEL FUNCTION 22 5 Multi channel Function Check Sheet ...
Страница 761: ...FA TRANSPARENT FUNCTION 23 FA TRANSPARENT FUNCTION 23 1 ...
Страница 762: ......
Страница 860: ...REVISIONS 4 ...
Страница 863: ......