14. CC-Link CONNECTION (Via G4)
14.5 PLC Side Settings
14 - 13
9
ME
LSE
C
NE
T
/H
CONN
E
C
TION
(P
LC
T
O
P
L
C NE
T
W
ORK)
10
MELSE
C
N
E
T/10
C
O
NNECTION (P
LC
TO
PL
C
N
E
T
W
O
R
K
)
11
C
C
-L
ink
IE
CO
NT
RO
LLER
NE
TW
ORK
CON
N
E
CTI
O
N
12
CC-Link
IE FIELD
NETWO
RK
CONNE
CTION
13
CC-
Li
nk
CONNECTI
O
N
(IN
TEL
LI
G
E
NT
DEVI
C
E
ST
AT
IO
N)
14
CC-Lin
k
CONNECTION
(V
ia G4)
15
IN
VER
TER
CONNE
C
T
ION
16
SE
R
V
O AM
P
L
IFI
E
R
CONN
E
C
T
ION
(3) Operation setting DIP switch
: Necessary : As necessary : Not necessary
*1
The peripheral connection module operates with the baud
rate set in the GOT.
14.5.6 [Controller Setting] of GT Designer3
POINT
POINT
POINT
Operation mode of peripheral connection module
Be sure to set the "Q mode" as an operation mode of
the peripheral connection module.
14.5.2 Connecting AJ65BT-R2N
This section describes the settings of the GOT and
peripheral connection module in the following case of the
system configuration.
POINT
POINT
POINT
(1) Peripheral connection module
For details of the peripheral connection module,
refer to the following manual.
Peripheral Connection Module Type AJ65BT-
R2N User's Manual
(2) CC-Link module
For details of the CC-Link module, refer to the
following manual.
CC-Link System Master/Local Module User's
Manual QJ61BT11N
(3) CC-Link built-in CPU
For details on the CC-Link function built-in CPU,
refer to the following manual.
MELSEC-L CC-Link System Master/Local
Module User's Manual
System configuration
*1
The Start I/O No. of the CC-Link module is set to "0"
Operation setting
DIP switch
Setting
Switch
Description
Set value
Setting
necessity
at GOT
connection
SW1,
SW6
Operation
mode
SW1 = OFF
SW6 = ON
(fixed)
(Q mode)
SW2
Peripheral
transmissi
on speed
*1
OFF (fixed)
SW3
SW4
Not used
OFF (fixed)
SW5
SW7
SW8
Test mode
OFF (fixed)
(Online mode)
SW
1
8
2 3 4 5 6 7
ON
<CC-Link module>
*1
Station type
Station No.
Mode
All connect count
Transmission speed
: Master station
: Station No. 0
: Remote net (Ver.1 mode)
: 1
: 156kbps
<AJ65BT-R2N>
Station type
Station No.
Number of stations occupied
Transmission speed
: Intelligent device station
: Station No. 1
: Exclusive station 1
: 156kbps
<GOT>
Transmission speed: 9600bps
Setting example
Setting example
Setting example
14.5.3 Switch setting of CC-Link module (Q series)
14.5.4 [Network parameter] of GX Developer
■
Содержание GT15
Страница 2: ......
Страница 34: ...A 32 ...
Страница 92: ......
Страница 110: ...2 18 2 DEVICE RANGE THAT CAN BE SET 2 9 MELSEC WS ...
Страница 134: ...3 24 3 ACCESS RANGE FOR MONITORING 3 7 Connection to the Head Module of CC Link IE Field Network System ...
Страница 186: ...5 10 5 BUS CONNECTION 5 2 System Configuration ...
Страница 218: ...5 42 5 BUS CONNECTION 5 4 Precautions ...
Страница 254: ...6 36 6 DIRECT CONNECTION TO CPU 6 6 Precautions ...
Страница 286: ...7 32 7 COMPUTER LINK CONNECTION 7 6 Precautions ...
Страница 350: ...8 64 8 ETHERNET CONNECTION 8 5 Precautions ...
Страница 368: ...9 18 9 MELSECNET H CONNECTION PLC TO PLC NETWORK 9 5 Precautions ...
Страница 420: ...11 26 11 CC Link IE CONTROLLER NETWORK CONNECTION 11 5 Precautions ...
Страница 440: ...12 20 12 CC Link IE FIELD NETWORK CONNECTION 12 5 Precautions ...
Страница 490: ...13 50 13 CC Link CONNECTION INTELLIGENT DEVICE STATION 13 5 Precautions ...
Страница 510: ......
Страница 564: ...15 54 15 INVERTER CONNECTION 15 7 Precautions ...
Страница 668: ......
Страница 712: ...21 12 21 MULTIPLE GT14 GT12 GT11 GT10 CONNECTION FUNCTION 21 5 Precautions ...
Страница 713: ...MULTI CHANNEL FUNCTION 22 MULTI CHANNEL FUNCTION 22 1 ...
Страница 714: ......
Страница 760: ...22 46 22 MULTI CHANNEL FUNCTION 22 5 Multi channel Function Check Sheet ...
Страница 761: ...FA TRANSPARENT FUNCTION 23 FA TRANSPARENT FUNCTION 23 1 ...
Страница 762: ......
Страница 860: ...REVISIONS 4 ...
Страница 863: ......