2 - 10
2. DEVICE RANGE THAT CAN BE SET
2.3 MELSEC-QnU/DC, Q17nD/M/NC/DR, CRnD-700
2.3 MELSEC-QnU/DC, Q17nD/M/NC/DR, CRnD-700
The table below shows the device ranges in [MELSEC-
QnU/DC, Q17nD/M/NC/DR, CRnD-700]
*9
as the controller
type.
*1
Do not set a file register by GT Designer3 when executing
multiple programs with the file of the file register set at [Use
the same file name as the program] by the PLC parameter of
GX Developer.
Otherwise, read/write at GOT will be erroneous.
*2
Available for file register of block No. switched with the RSET
instruction.
*3
Available for file register of block No. of file name switched
with the QDRSET instruction.
*4
Only the intelligent function module on the station connected
to GOT can be specified.
Set within the address range of the buffer memory existing in
the target intelligent function module.
*5
Do not use local devices set in the MELSEC-Q system.
Otherwise, normal monitoring is not performed.
*6
Even though Universal model QCPU processes 64-bit data,
the GOT cannot monitor 64-bit data.
*7
This is not supported by GT10.
*8
This cannot be monitored when in GOT multi-drop
connection.
*9
For GT14, GT11 and GT10, the controller type is as follows.
• GT14, GT11: MELSEC-QnU/DC, Q17nD/M/NC/DR
• GT10: MELSEC-QnU/DC
*10
For monitoring the internal relay (M) or data register (D) of a
C Controller module (Q Series), configure the settings
related to the device functions in the device setting tab of the
language controller setting utility.
*11
The device No. must be set in multiples of 16.
*12
To continuously write the Q172DR (CR750-Q), use the
Q172DR (CR750-Q) Ver.R6b or later.
Device name
*6*12
Setting range
Device No.
representation
B
it device
Input (X)
X0
to
X3FFF
Hexadecimal
Output (Y)
Y0
to
Y3FFF
Internal relay (M)
*5*10
M0
to
M61439
Decimal
Latch relay (L)
L0
to
L32767
Annunciator (F)
F0
to
F32767
Link relay (B)
B0
to
B9FFFF
Hexadecimal
Timer
*5
Contact (TT)
TT0
to
TT32767
Decimal
Coil (TC)
TC0
to
TC32767
Counter
*5
Contact (CT)
CT0
to
CT32767
Coil (CC)
CC0
to
CC32767
Special relay (SM)
SM0
to
SM2255
Retentive
timer
*5
Contact (SS)
SS0
to
SS32767
Coil (SC)
SC0
to
SC32767
Step relay (S)
S0
to
S32767
Link special relay (SB)
SB0
to
SB7FFF
Hexadecimal
The bit specification of the
word device
(except Timer, Counter,
Retentive timer, Index
register)
Setting range of each
word device
―
W
o
rd
device
Data register (D)
*5*10
D0
to
D4910079
Decimal
Special data register (SD)
SD0
to
SD2255
Link register (W)
W0
to
W4AEBFF
Hexadecimal
Timer (current value) (TN)
*5
TN0
to
TN32767
Decimal
Counter (current value)
(CN)
*5
CN0
to
CN32767
Retentive timer
(current value) (SN)
*5
SN0
to
SN32767
Link special register (SW)
SW0 to
SW7FFF
Hexadecimal
File register (R)
*1*2
R0
to
R32767
Decimal
Extension
file register
(ER)
*1
Block
0
to
255
Device
ER0
to
ER32767
Extension file register
(ZR)
*1*3
ZR0
to
ZR4849663
Index register (Z)
Z0
to
Z19
Buffer memory
(Intelligent function module)
(BM)
*4
BM0
to
BM32767
Buffer memory
(Intelligent function module)
(G)
*4
G0
to
G65535
Ww
*7*8
Ww0 to
Ww1FFF
Hexadecimal
Wr
*7*8
Wr0
to
Wr1FFF
Multiple CPU high speed
transmission memory (U3E0)
U3E010000 to U3E024335
Multiple CPU high speed
transmission memory (U3E1)
U3E110000 to U3E124335
Multiple CPU high speed
transmission memory (U3E2)
U3E210000 to U3E224335
Multiple CPU high speed
transmission memory (U3E3)
U3E310000 to U3E324335
W
o
rd
device
Motion device (#)
#0
to
#12287
Decimal
The word specification of
the bit device
*7*11
(except Timer, Counter,
Retentive timer)
Setting range of each bit
devices
―
Device name
*6*12
Setting range
Device No.
representation
Содержание GT15
Страница 2: ......
Страница 34: ...A 32 ...
Страница 92: ......
Страница 110: ...2 18 2 DEVICE RANGE THAT CAN BE SET 2 9 MELSEC WS ...
Страница 134: ...3 24 3 ACCESS RANGE FOR MONITORING 3 7 Connection to the Head Module of CC Link IE Field Network System ...
Страница 186: ...5 10 5 BUS CONNECTION 5 2 System Configuration ...
Страница 218: ...5 42 5 BUS CONNECTION 5 4 Precautions ...
Страница 254: ...6 36 6 DIRECT CONNECTION TO CPU 6 6 Precautions ...
Страница 286: ...7 32 7 COMPUTER LINK CONNECTION 7 6 Precautions ...
Страница 350: ...8 64 8 ETHERNET CONNECTION 8 5 Precautions ...
Страница 368: ...9 18 9 MELSECNET H CONNECTION PLC TO PLC NETWORK 9 5 Precautions ...
Страница 420: ...11 26 11 CC Link IE CONTROLLER NETWORK CONNECTION 11 5 Precautions ...
Страница 440: ...12 20 12 CC Link IE FIELD NETWORK CONNECTION 12 5 Precautions ...
Страница 490: ...13 50 13 CC Link CONNECTION INTELLIGENT DEVICE STATION 13 5 Precautions ...
Страница 510: ......
Страница 564: ...15 54 15 INVERTER CONNECTION 15 7 Precautions ...
Страница 668: ......
Страница 712: ...21 12 21 MULTIPLE GT14 GT12 GT11 GT10 CONNECTION FUNCTION 21 5 Precautions ...
Страница 713: ...MULTI CHANNEL FUNCTION 22 MULTI CHANNEL FUNCTION 22 1 ...
Страница 714: ......
Страница 760: ...22 46 22 MULTI CHANNEL FUNCTION 22 5 Multi channel Function Check Sheet ...
Страница 761: ...FA TRANSPARENT FUNCTION 23 FA TRANSPARENT FUNCTION 23 1 ...
Страница 762: ......
Страница 860: ...REVISIONS 4 ...
Страница 863: ......