This manual confers no industrial property rights or any rights of any other
kind, nor does it confer any patent licenses. Mitsubishi Electric Corporation
cannot be held responsible for any problems involving industrial property rights
which may occur as a result of using the contents noted in this manual.
Warranty
Exclusion of loss in opportunity and secondary loss from warranty liability
Regardless of the gratis warranty term, Mitsubishi shall not be liable for
compensation to:
(1) Damages caused by any cause found not to be the responsibility of
Mitsubishi.
(2) Loss in opportunity, lost profits incurred to the user by Failures of Mitsubishi
products.
(3) Special damages and secondary damages whether foreseeable or not,
compensation for accidents, and compensation for damages to products
other than Mitsubishi products.
(4) Replacement by the user, maintenance of on-site equipment, start-up test run
and other tasks.
For safe use
This product has been manufactured as a general-purpose part for general
industries, and has not been designed or manufactured to be incorporated in
a device or system used in purposes related to human life.
Before using the product for special purposes such as nuclear power, electric
power, aerospace, medicine or passenger movement vehicles, consult with
Mitsubishi Electric.
This product has been manufactured under strict quality control. However
when installing the product where major accidents or losses could occur if the
product fails, install appropriate backup or failsafe functions in the system.
HEAD OFFICE : TOKYO BUILDING, 2-7-3 MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN
Side
A
Side
B
JAPANESE
ENGLISH
JY997D25301T
Side
B
Safety Precaution
(Read these precautions before using.)
Before using this product, please read this manual and the relevant manuals introduced
in this manual carefully and pay full attention to safety to handle the product correctly.
The precautions given in this manual are concerned with this product.
In this manual, the safety precautions are ranked as "WARNING" and
"CAUTION".
Depending on circumstances, procedures indicated by "CAUTION" may also be
linked to serious results.
In any case, it is important to follow the directions for usage.
Indicates that incorrect handling may cause hazardous
conditions, resulting in death or severe injury.
Indicates that incorrect handling may cause hazardous
conditions, resulting in medium or slight personal injury
or physical damage.
DESIGN PRECAUTIONS
Some failures of the GOT or cable may keep the outputs on or off.
An external monitoring circuit should be provided to check for output signals
which may lead to a serious accident.
Not doing so can cause an accident due to false output or malfunction.
If a communication fault (including cable disconnection) occurs during
monitoring on the GOT, communication between the GOT and PLC CPU is
suspended and the GOT becomes inoperative.
A system where the GOT is used should be configured to perform any
significant operation to the system by using the switches of a device other
than the GOT on the assumption that a GOT communication fault will occur.
Not doing so can cause an accident due to false output or malfunction.
Do not use the GOT as the warning device that may cause a serious accident.
An independent and redundant hardware or mechanical interlock is required to
configure the device that displays and outputs serious warning.
Failure to observe this instruction may result in an accident due to incorrect
output or malfunction.
Incorrect operation of the touch switch(s) may lead to a serious accident if the
GOT backlight is gone out. When the GOT backlight goes out, causes the
monitor screen to appear blank, while the input of the touch switch(s) remains
active. This may confuse an operator in thinking that the GOT is in
"screensaver" mode, who then tries to release the GOT from this mode by
touching the display section, which may cause a touch switch to operate.
DESIGN PRECAUTIONS
Do not bundle the control and communication cables with main-circuit, power
or other wiring.
Run the above cables separately from such wiring and keep them a minimum
of 100mm (3.94in.) apart.Not doing so noise can cause a malfunction.
Do not press the GOT display section with a pointed material as a pen or
driver. Doing so can result in a damage or failure of the display section.
Before connecting to GOT, turn ON the controller to enable the
communication. When the communication of controller is not available, a
communication error may occur in GOT.
MOUNTING PRECAUTIONS
Be sure to shut off all phases of the external power supply used by the system
before mounting or removing the GOT to/from the panel.
Not doing so can cause the unit to fail or malfunction.
When installing the battery wear an earth band etc. to avoid the static electricity.
The static electricity can cause the unit to fail or malfunction.
MOUNTING PRECAUTIONS
Use the GOT in the environment that satisfies the general specifications
described in this manual. Not doing so can cause an electric shock, fire,
malfunction or product damage or deterioration.
When mounting the GOT to the control panel, tighten the mounting screws in the
specified torque range. Undertightening can cause the GOT to drop, short circuit
or malfunction, and deteriorate the waterproof effect and oilproof effect.
Overtightening can cause a drop, short circuit or malfunction due to the damage
of the screws or the GOT, and deteriorate the waterproof effect and oilproof effect
due to distortion of the protective cover for oil, GOT or panel.
When using the GOT in the environment of oil or chemicals, use the protective
cover for oil. Failure to do so may cause failure or malfunction due to the oil or
chemical entering into the GOT.
WIRING PRECAUTIONS
Be sure to shut off all phases of the external power supply used by the system
before wiring. Failure to do so may result in an electric shock, product damage or
malfunctions.
Please make sure to ground FG terminal of the GOT power supply section by
applying 100 or less which is used exclusively for the GOT. Not doing so may
cause an electric shock or malfunction.
Correctly wire the GOT power supply section after confirming the rated voltage
and terminal arrangement of the product. Not doing so can cause a fire or failure.
Tighten the terminal screws of the GOT power supply section in the specified
torque range. Undertightening can cause a short circuit or malfunction.
Overtightening can cause a short circuit or malfunction due to the damage of the
screws or the GOT.
Exercise care to avoid foreign matter such as chips and wire offcuts entering the
GOT. Not doing so can cause a fire, failure or malfunction.
WIRING PRECAUTIONS
Plug the communication cable into the connector of the connected unit and
tighten the mounting and terminal screws in the specified torque range.
Undertightening can cause a short circuit or malfunction. Overtightening can
cause a short circuit or malfunction due to the damage of the screws or unit.
TEST OPERATION
PRECAUTIONS
Before performing the test operations of the user creation monitor screen (such as
turning ON or OFF bit device, changing the word device current value, changing
the settings or current values of the timer or counter), read through the manual
carefully and make yourself familiar with the operation method.
During test operation, never change the data of the devices which are used to
perform significant operation for the system. False output or malfunction can
cause an accident.
STARTUP/MAINTENANCE
PRECAUTIONS
When power is on, do not touch the terminals.
Doing so can cause an electric shock or malfunction.
Connect the battery correctly. Do not discharge, disassemble, heat, short, solder or
throw the battery into the fire. Incorrect handling may cause the battery to
generate heat, burst or take fire, resulting in injuries or fires.
Before starting cleaning or terminal screw retightening, always switch off the
power externally in all phases. Not switching the power off in all phases can cause
a unit failure or malfunction. Undertightening can cause a short circuit or
malfunction. Overtightening can cause a short circuit or malfunction due to the
damage of the screws or unit.
STARTUP/MAINTENANCE
PRECAUTIONS
Do not disassemble or modify the unit.
Doing so can cause a failure, malfunction, injury or fire.
Do not touch the conductive and electronic parts of the unit directly.
Doing so can cause a unit malfunction or failure.
The cables connected to the unit must be run in ducts or clamped.
Not doing so can cause the unit or cable to be damaged due to the dangling,
motion or accidental pulling of the cables or can cause a malfunction due to a
cable connection fault.
When unplugging the cable connected to the unit, do not hold and pull the cable
portion. Doing so can cause the unit or cable to be damaged or can cause a
malfunction due to a cable connection fault.
Compliance with EC directive (CE Marking)
This note does not guarantee that an entire mechanical module produced in
accordance with the contents of this note will comply with the following standards.
Compliance to EMC directive for the entire mechanical module should be checked by
the user / manufacturer. For more details please contact the local Mitsubishi Electric
sales site.
Attention
This product is designed for use in industrial applications.
Requirement for Compliance with EMC directive
The following products have shown compliance through direct testing (to the
identified standards) and design analysis (forming a technical construction file) to the
European Directive for Electromagnetic Compatibility (2004/108/EC) when used as
directed by the appropriate documentation.
Type :Programmable Controller (Open Type Equipment)
For more details please contact the local Mitsubishi Electric sales site.
Notes for compliance to EMC regulation
1) General notes on the use of communication cables
Any device which utilizes a data communication function is susceptible to the
wider effects of local EMC noise. Therefore, when installing any communication
cables care should always be taken with the routing and location of those cables.
The GOT units identified on the previous chapter are compliant with the EMC
requirement when the following communication cables are used.
2) General notes on the use of the power cable
The GT1030-H
D/H
D2/H
DW/H
DW2 unit demand that the cable for the
power supply is 10m or less.
Associated Manuals
The following manuals are relevant to this product. When these loose manuals are
required, please consult with our local distributor.
*1 Stored in the GT Works3/GT Designer3 in PDF format.
For details of a PLC to be connected, refer to the PLC user's manual respectively.
Bundled Items
STARTUP/MAINTENANCE
PRECAUTIONS
Do not drop or apply any impact to the battery.
If any impact has been applied, discard the battery and never use it.
The battery may be damaged by the drop or impact.
Before touching the unit, always touch grounded metal, etc. to discharge static
electricity from human body, etc.
Not doing so can cause the unit to fail malfunction.
Replace battery with GT11-50BAT by Mitsubishi electric Co. only.
Use of another battery may present a risk of fire or explosion.
Dispose of used battery promptly.
Keep away from children. Do not disassemble and do not dispose of in fire.
DISPOSAL PRECAUTIONS
When disposing of the product, handle it as industrial waste.
When disposing of batteries, separate them from other wastes according to the
local regulations. (For details of the battery directive in EU member states, refer
GOT User’s Manual.)
TRANSPORTATION
PRECAUTIONS
When transporting lithium batteries, make sure to treat them based on the
transport regulations. (Refer to User's Manual for details of the regurated
models.)
Before transporting the GOT, turn the GOT power on and check that the battery
voltage status is normal on the Time setting & display screen (utilities screen). In
addition, confirm that the adequate battery life remains on the rating plate.
Transporting the GOT with the low battery voltage or the battery the reached
battery life may unstabilize the backup data unstable during transportation.
Make sure to transport the GOT main unit and/or relevant unit(s) in the manner
they will not be exposed to the impact exceeding the impact resistance
described in the general specifications of this manual, as they are precision
devices. Failure to do so may cause the unit to fail.
Check if the unit operates correctly after transportation.
Standard
Remark
EN61131-2 : 2007
Programmable
controllers- Equipment,
requirement and tests
EMI
Compliance with all relevant aspects of the
standard. (Radiated Emissions)
EMS
Compliance with all relevant aspects of the
standard. (ESD,RF electromagnetic field, EFTB,
Surge, RF conducted disturbances and Power
frequency magnetic field)
GOT Unit
Existing Cables
GT1030-HBD/HWD/HBL/HWL/HBDW/HWDW/
HBLW/HWLW
GT10-C30R4-8P
(For Melsec FX series PLC)
GT1030-HBD2/HWD2/HBDW2/HWDW2
GT10-C30R2-6P
(For Melsec Q series PLC)
Manual name
Contents
Manual Number
(Model Code)
GT10 User's Manual
(sold separately)
Describes the GT10 hardware-
r e l e v a n t c o n t e n t s u c h a s pa r t
n a m e s , e x t e r n a l d i m e n s i o n s ,
mounting, power supply wiring,
specifications, and introduction to
option devices
JY997D24701
(09R819)
GT Designer3 Version1
Screen Design Manual
(For GOT1000 Series)
(Fundamentals)1/2, 2/2
(sold separately)
*1
D e s c r i b e s m e t h o d s o f t h e G T
Designer3 installation operation,
basic operation for drawing and
transmitting data to GOT1000 series
SH-080866ENG
(1D7MB9)
GT Designer3 Version1
Screen Design Manual
(For GOT1000 Series)
(Functions) 1/2, 2/2
(sold separately)
*1
D e s c r i b e s s p e c i f i c a t i o n s a n d
settings of the object functions used
in GT Designer3
SH-080867ENG
(1D7MC1)
GOT1000 Series
Connection Manual
(Mitsubishi Products)
for GT Works3
(sold separately)
*1
Describes system configurations of
the connection method applicable to
GOT1000 series and cable creation
method
SH-080868ENG
(1D7MC2)
Model Name
Remark
GT1030-HBD/HWD
GOT main unit
(The maintenance supplies below
are packed with the product.)
GT1030-HBD2/HWD2
GT1030-HBL/HWL
GT1030-HBDW/HWDW
GT1030-HBDW2/HWDW2
GT1030-HBLW/HWLW
Maintenance Supplies
Quantity
PLC Communication Connector
1
Panel Mounting Bracket (with M4
20 screws)
4
Panel Mounting Packing
1
GT10 General Description (This manual)
1
2:RS-232
Blank:RS-422
Explanation of the GOT model name
GT10 3 0 -
* * * * *
0:Monochrome(black/white)
H:STN monochrome(High contrast)
GOT1000 series GT10
Screen size type
Display color type
Display device type
B:Black
W:White
Power type
Panel color type
D:24VDC
L:5VDC
3:4.5"
Backlight type
W:white/red/pink
Blank:green/red/orange
Interface type for
communication with PLC
1. Specifications
1.1 General Specifications
*1 Do not use or store the GOT under pressure higher than the atmospheric
pressure of altitude 0m (0ft.). Failure to observe this instruction may cause a
malfunction.
When the air inside the control panel is purged by pressurization, the surface
sheet may be lifted by high pressure. As a result, the touch panel may be
difficult to press, and the sheet may be peeled off.
*2 This indicates the section of the power supply to which the equipment is
assumed to be connected between the public electrical power distribution
network and the machinery within the premises.
Category II applies to equipment for which electrical power is supplied from
fixed facilities.
The surge voltage withstand level for up to the raged voltage of 300 V is 2500 V.
*3 This index indicates the degree to which conductive material is generated in
the environment where the equipment is used.
In pollution degree 2, only non-conductive pollution occurs but temporary
conductivity may be produced due to condensation.
1.2 Performance Specifications
*1
Bright dots (always lit) and dark dots (unlit) may appear on a liquid crystal
display panel. It is impossible to completely avoid this symptom, as the liquid
crystal display comprises of a great number of display elements. Flickers may
be observed depending on the display color.
Please note that these dots appear due to its characteristic and are not
caused by product defect.
Flickers and partial discoloration may be generated on the liquid crystal
display panel due to the display contents or the contrast adjustment.
However, please note that these phenomena appear due to its characteristic
and are not caused by product defect.
There is a difference in the display brightness and the color tones between
liquid crystal display panels. When using multiple liquid crystal display panels,
please note that there is an individual difference between them.
A crosstalk (shadow as an extension of the display) may appear on the liquid
crystal display panel. Please note that it appears due to its characteristic.
When the display section is seen from the outside of the display angle, the
display color seems like it has changed.
Please note that it is due to its characteristic. Please note that the response
time, brightness and color of the liquid crystal display panel may vary
depending on the usage environmental temperature.
Especially in the low temperature environment, the display response
becomes slow due to the characteristics of the STN liquid crystal.
Please check the display response in advance for using this product.
Please note that the response in low temperatures tend to be slower as a
characteristic of the liquid crystal display panel.
When the same screen is displayed for a long time, an incidental color or
partial discoloration is generated on the screen due to heat damage, and it
may not disappear.
To prevent heat damage, the screen saver function is effective.
For details of the screen saver function, refer to the following.
GT10 User's Manual
*2 For the details of system information, refer to the following.
GT Designer3 Version1 Screen Design Manual
*3 ROM in which new data can be written without deleting the written data.
*4 Note that this does not guarantee all users' operation environment.
In addition, the product may not be used in environments under exposition of
oil or chemicals for a long period of time, or in environments filled with oil-mist.
1.3 Communication Specifications
Item
Specifications
GT1030-H
D/H
D2/H
L/H
DW/H
DW2/H
LW
Operating
ambient
tempera-
ture
Display
section
0 to 50
C
Other than
display
section
0 to 55
C (When mounted horizontally), 0 to 50
C (When
mounted vertically)
Storage ambient
temperature
-20 to 60
C
Operating/Storage
ambient humidity
10 to 90% RH, non-condensing (The wet bulb temperature
is 39
C or less.)
Vibration resistance
Con-
forms
to JIS
B3502
and
IEC61131
-2
Fre-
quency
Acceler-
ation
Half-
ampli-
tude
Sweep
Count
U n d e r
intermit-
t e n t
vibration
5 to
8.4Hz
--
3.5mm
10 times
each in
X, Y
and Z
direc-
tions
8.4 to
150Hz
9.8m/s
2
--
U n d e r
c on ti nu -
o u s
vibration
5 to
8.4Hz
--
1.75mm
8.4 to
150Hz
4.9m/s
2
--
Shock resistance
Conforms to JIS B3502, IEC 61131-2 (147m/s
2
, 11 ms, Sine
half-wave pulse, 3 times each in the X, Y, and Z directions.)
Operating atmosphere
Must be free of lamp black, corrosive gas, flammable gas,
or excessive amount of electro conductive dust particles
and must be no direct sunlight. (Same as for saving)
Operating altitude
*1
2000 m (6562 ft) max.
Installation location
Inside control panel
Overvoltage
category
*2
II or less
Pollution degree
*3
2 or less
Cooling method
Self-cooling
Item
Specifications
GT1030-
H
D/H
D2
GT1030-
H
L
GT1030-
H
DW/
H
DW2
GT1030-
H
LW
Display
section
*
1
Type
STN monochrome (white/black) liquid crystal
Screen size
4.5"
Resolution
288
96 dots (Horizontal format)
Display size W109.42(4.3)
H35.98(1.41) [mm](inch) (Horizontal
format)
Display
section
*
1
D i s p l a y
character
16-dot standard font: 36 characters
6 lines, 12-dot
standard font: 48 characters
8 lines (Horizontal format)
Display color Monochrome (white/black)
Display angle Left/Right: 30 degrees, Top: 20 degrees, Bottom: 30
degrees (Horizontal format)
C o n t r a s t
adjustment
16-level adjustment
Intensity of
LCD only
200 [cd/m
2
] (in green)
500 [cd/m
2
] (in white)
I n t e n s i t y
adjustment
8-level adjustment
Life
Approx. 50,000h. (Time for display intensity to become 1/5
at operating ambient temperature of 25
C)
Backlight (no
replacement required)
LED with 3 available colors
(green, red, orange)
LED with 3 available colors
(white, red, pink)
Backlight status (colors, ON/BLINK/OFF) control,
Adjustable screensaver activation time
Setting the system information enables
*2
PLC to control the
backlight status
Touch
panel
N u m b e r o f
touch keys
Maximum 50 keys/screen (Matrix resistive film touch panel)
Key size
Minimum 16
16 dots (per key)
Simultaneous
pres si ng o f
two (or
more) areas
( 2 - p o i n t
press)
Enable
Life
1 million times or more (operating force 0.98N max.)
Memory
C drive
*3
Flash memory ROM (Internal), for storing Project data
(1.5M bytes or less), OS
L i f e
(Number of
write times)
100,000 times
D drive
SRAM (Internal), for storing alarm history, recipe data and
time action setting value
Battery
GT11-50BAT lithium battery
Type
Magnesium maganese dioxide lithium primary battery
Backup
target
Clock data, alarm history and recipe data
Life
Approx. 5 years (Operating ambient temperature of 25)
Buzzer output
(a buzzer that sounds
when touch keys are
pressed)
Single tone (LONG/ SHORT/ OFF adjustable)
E n v i r o n m e n t a l
protective structure
*4
Equivalent to IP67 (JEM1030) (front section)
External dimensions
W145(5.7)
H76(2.99)
D29.5(1.16)[mm](inch) (Excluding
mounting fixtures) (Horizontal format)
Panel cutting
dimensions
W137(5.39)
H66(2.59) [mm](inch) (Horizontal format)
Weight (Excluding
mounting fixtures)
0.3kg
0.28kg
0.3kg
0.28kg
Compatible software
package
GT Designer3 Version1.19V or later
Item
Specifications
GT1030-
H
D/H
DW
GT1030-
H
D2/H
DW2
GT1030-
H
L/H
LW
PLC
communication
Communication
standard
R S - 4 2 2 / 4 8 5
1ch
RS-232 1ch
RS-422 1ch
Tran sm is si on
speed
115,200/57,600/38,400/19,200/9,600/4,800bps
C o n n e c t o r
shape
Connector terminal block 9-pins
Item
Specifications
GT1030-
H
D/H
D2
GT1030-
H
L
GT1030-
H
DW/
H
DW2
GT1030-
H
LW
*1 Set the terminating resistor selector switch of the GOT in accordance with the
connection type when adopting GOT multidrop connection.
For details of GOT multidrop connection, refer to the following.
GOT1000 Series Connection Manual (Mitsubishi Products) for GT Works3
*2 Project data upload/download, OS installation, Transparent function
1.4 Power Supply Specifications
(
For details on power supply wiring, such as the allowable cable size and tightening
torque, refer to the additional manual, "GT10 User's Manual".)
*1 The GOT continues to operate even upon 5ms or shorter instantaneous
power failure. The GOT stops operating if there is extended power failure or
voltage drop, while it automatically resumes operation as soon as the power is
restored.
2. Wiring of connection cable
The diagram below shows cable assignment for GOT port.
Cables: GT10-C
R4-8P, GT10-C
R4-2P, GT10-C
R2-6P
User-made cable is necessary, depending on the PLC.
For the detail, refer to GOT1000 Series Connection Manual (Mitsubishi Products) for
GT Works3.
「电器电子产品有害物质限制使用标识要求」的表示方式
Note: This symbol mark is for China only.
含有有害6物质的名称,含有量,含有部品
本产品中所含有的有害 6 物质的名称,含有量,含有部品如下表所
示。
产品中有害物质的名称及含量
本表格依据SJ/T 11364的规定编制。
○:表示该有害物质在该部件所有均质材料中的含量均在GB/T 26572
规定的限量要求以下。
×:表示该有害物质至少在该部件的某一均质材料中的含量超出GB/T
26572规定的限量要求。
PLC
communication
Te r m i n a t i n g
resistor
*1
O p e n / 11 0
/
330
(Switched
by
t e r m i n a t i n g
resistor selector
switch)
(At factory
s h i p m e n t :
330
)
--
--
PC
c o m m u n i c a -
tion
*2
Communication
standard
RS-232 1ch
Tra ns mis si on
speed
115,200/57,600/38,400/19,200/9,600/4,800bps
C o n n e c t o r
shape
MINI DIN 6-pins (Female)
Item
Specifications
GT1030-H
D/H
D2/H
DW/
H
DW2
GT1030-H
L/H
LW
Input power supply
voltage
24VDC (+10% -15%),
ripple voltage 200mV or less
5VDC (
5%),
supplied from the PLC
F u s e ( b u i l t - i n , n o t
exchangeable)
0.5A
--
Power consumption,
(At backlight off)
2.2W (90mA/24VDC) or less,
(1.7W (70mA/24VDC) or less)
1 .1 W ( 22 0 mA /5 V D C ) or
less, (0.6W (120mA/5VDC)
or less)
Inrush current
18A or less (26.4VDC) 1ms
--
P e r m i s s i b l e
instantaneous power
failure time
*1
Within 5ms
--
Noise immunity
Noise voltage: 1000Vp-p, Noise width: 1
s (by noise
simulator of 30 to 100Hz noise frequency)
Dielectric withstand
voltage
5 0 0 VA C f o r 1 m i n u t e
(between the GOT’s power
s upply terminals and the
GOT’s grounding terminal)
--
Insulation resistance
10M
or larger by insulation
resistance tester (between the
GOT’s power supply terminals
and the GOT’s grounding
terminal)
--
Grounding
G rou nding w ith a ground
resistance of 100
Ω
or less by
using a ground cable that has
a cross-sectional area of 0.14
to 1.5 mm
2
(solid wire), 0.14
to 1.0 mm
2
(stranded wire), or
0.25 to 0.5 mm
2
(rod terminal
with an insulation sleeve).
If impossible, connect the
ground cable to the control
panel.
--
Item
Specifications
GT1030-
H
D/H
DW
GT1030-
H
D2/H
DW2
GT1030-
H
L/H
LW
PLC connection cable
GOT
PLC
GT10-C R4-8P
24V
GOT
5V
CSB
CSA
SDA
SDB
RDA
RDB
SG
RSA
RSB
Untied
wire
color
Brown
Red
Orange
Yellow
Green
Black
White
GT10-C R4-25P
24V
SDA
SDB
RDA
RDB
SG
RSA
RSB
CSB
CSA
GT10-C R2-6P
GOT
SD
RD
ER
DR
SG
RS
CS
NC
NC
Blue
Yellow
Green
Purple
Blue
Purple
24V
-
+
(terminal
block)
GOT
Untied
wire
color
(terminal
block)
Brown
Red
Orange
Yellow
Green
Black
White
(terminal
block)
Brown
Red
Untied
wire
color
Cable jacket to remove
7mm (0.27")
Tightening torque
0.22 to 0.25 N
m
Recommended Tool (Screwdriver)
SZS 0.4
2.5 (Phoenix Contact Inc.)
部件名称
有害物质
铅
(Pb)
汞
(Hg)
镉
(Cd)
六价铬
(Cr(VI))
多溴联苯
(PBB)
多溴
二苯醚
(PBDE)
显 示 器
GOT
外壳
○
○
○
○
○
○
印刷基板
×
○
○
○
○
○
背光灯
(CCFL)
○
×
○
○
○
○
电缆
×
○
○
○
○
○
GT1030-H
D(W)/H
D(W)2/H
L(W)
GT10 General Description
This manual describes the specifications of the product. Before use, read this
manual and manuals of relevant products fully to acquire proficiency in handling
and operating the product. Make sure to learn all the product information, safety
information, and precautions.
And, store this manual in a safe place so that you can take it out and read it
whenever necessary. Always forward it to the end user.
Registration
The company name and the product name to be described in this manual are the
registered trademarks or trademarks of each company.
Effective Oct. 2016
Specifications are subject to change without notice.
2008 MITSUBISHI ELECTRIC CORPORATION
Manual Number
JY997D25301T
Date
Oct. 2016