14
─
(5) Remove the resistor assembly
.
[1] Remove the under cover. See (3) [1].
[2] Disconnect the switch connectors. See (3) [2].
Resistor assembly
[3] Unscrew the screws (PTT screws 4x6, indicated by
), and remove the resistor assembly.
Model
The number of
screws and ce-
ment resistors
Resistance
GK-2509YS2-CE
2
85
Ω
GK-2512AS2-CE
2
85
Ω
GK-3009AS2-CE
3
60
Ω
GK-3012AS2-CE
3
50
Ω
[4] Cut the crimp cap that is connected to the three-pin
connector at the position indicated by
to re-
place the resistor assembly.
Three-pin connector
Crimp cap
(6) Remove the cord assembly.
[1] Disconnect the power wires (L, N) and earth lead wire. See (2) [1].
[2] Dismount the main unit from the body fix plate. See (2) [2].
[3] Remove the under cover. See (3) [1].
[4] Disconnect the ON/OFF switch connector. See (3) [2].
[5] Unscrew the screw (one PT screw 4x8, indicated
by ) that is fixed on the frame assembly, and
remove the earth lead wire from the unit.
Earth lead wire
BLACK
BLUE
BROWN
YELLOW/GREEN
Cord assembly
[6] Cut the crimp cap (indicated by ) to disconnect the motor connection.
See (3) [3] for cutting of the crimp cap.
Precaution
When cutting the crimp cap, keep the length of the
lead wires as long as possible.
If the lead wires are too short, they cannot be
reconnected after the replacement.
Frame assembly