4
Cable Size and Crimping Terminal
ENGLISH
4
Cable Size and Crimping Terminal
Refer to
page 3
for the wiring of terminals P and P1 and the earthing cable.
* Torque value (reference value) for the iron bolts with the 4.6 strength rating. Use the tightening
torque recommended for the applied bolt.
Model
P, P1
Earth (ground) cable
Terminal
bolt size
Tightening
torque*
N
m
Crimping
terminal
AWG/
MCM
Crimping
terminal
AWG/
MCM
FR-HEL-C75K
M10
26.5
60-10
1/0
38-6
1
FR-HEL-C90K
M10
26.5
70-10
2/0
38-6
1
FR-HEL-C110K
M10
26.5
80-10
3/0
38-6
1
FR-HEL-C132K
M12
46.1
100-12
4/0
38-6
1
FR-HEL-C185K
M12
46.1
150-12
300
38-6
1
FR-HEL-C220K
M12
46.1
100-12
2×4/0
60-6
1/0
FR-HEL-C280K
M12
46.1
150-12
2×300
100-8
4/0