Installation and wiring
Control circuit
FR-F800
2 - 65
Safety stop function operation
ON: Transistor used for an open collector output is conducted.
OFF: Transistor used for an open collector output is not conducted.
When not using the safety stop function, short across terminals S1 and PC, S2 and PC, and SIC and
SD to use the inverter. (In the initial status, terminals S1 and PC, S2 and PC, and SIC and SD are
respectively shorted with shorting wires.)
If any of the protective functions shown in the following table is activated, the terminal SO and
the SAFE output signal turn OFF.
If the internal safety circuit is operated normally, the terminal SO and the SAFE output signal remain
ON until E.SAF is displayed, and the terminal SO and the SAFE output signal turn OFF when E.SAF
is displayed.
!
SA is displayed when the terminals S1 and S2 are identified as OFF due to the internal safety circuit
failure.
If another fault occurs at the same time as E.SAF, the other fault can be displayed.
$
If another warning occurs at the same time as SA, the other warning can be displayed.
Input power
Internal
safety circuit
status
Input terminal
,
Output
terminal
Output
signal
Inverter running
status
Operation panel indication
S1
S2
SO
SAFE
E.SAF
OFF
⎯
⎯
⎯
OFF
OFF
Output shutoff
(Safe state)
Not displayed Not displayed
ON
Normal
ON
ON
OFF
Drive enabled
Not displayed Not displayed
Normal
ON
OFF
OFF
Output shutoff
(Safe state)
Displayed
Displayed
Normal
OFF
ON
OFF
Output shutoff
(Safe state)
Displayed
Displayed
Normal
OFF
OFF
ON
Output shutoff
(Safe state)
Not displayed
Displayed
Fault
ON
ON
OFF
OFF
Output shutoff
(Safe state)
Displayed
Not displayed
Fault
ON
OFF
OFF
OFF
Output shutoff
(Safe state)
Displayed
Displayed
Fault
OFF
ON
OFF
OFF
Output shutoff
(Safe state)
Displayed
Displayed
Fault
OFF
OFF
OFF
OFF
Output shutoff
(Safe state)
Displayed
Displayed
Tab. 2-27:
Description of Safety stop function operation
Fault record
Operation panel
indication
Fault record
Operation panel
indication
Option fault
E.OPT
24 V DC power fault
E.P24
Communication option fault
E.OP1
Safety circuit fault
E.SAF
Parameter storage device fault
E.PE
Overspeed occurrence
E.OS
Retry count excess
E.RET
CPU fault
E.CPU
Parameter storage device fault
E.PE2
E.5 to E.7
Operation panel power supply
short circuit/
RS-485 terminal power supply
short circuit
E.CTE
Internal circuit fault
E.13
Tab. 2-28:
Indication of internal safety circuit failures
Содержание FR-F820-00046
Страница 2: ......
Страница 4: ......
Страница 114: ...System configuration for Ethernet communication FR F800 E Installation and wiring 2 86 ...
Страница 172: ...Basic operation procedure JOG operation Basic operation 4 32 ...
Страница 812: ...Inverter to inverter link function FR F800 E Parameters 5 640 ...
Страница 874: ...Measurement of main circuit voltages currents and powers Precautions for maintenance and inspection 7 20 ...
Страница 900: ...Outline dimension drawings Specifications 8 26 ...
Страница 928: ...EC Declarations of Conformity Appendix A 28 A 6 EC Declarations of Conformity A 6 1 FR F820 FR F840 FR F842 series ...
Страница 929: ...Appendix EC Declarations of Conformity FR F800 A 29 ...
Страница 930: ...EC Declarations of Conformity Appendix A 30 ...
Страница 931: ...Appendix EC Declarations of Conformity FR F800 A 31 ...
Страница 932: ...EC Declarations of Conformity Appendix A 32 ...
Страница 933: ...Appendix EC Declarations of Conformity FR F800 A 33 ...
Страница 934: ...EC Declarations of Conformity Appendix A 34 ...
Страница 935: ...Appendix EC Declarations of Conformity FR F800 A 35 ...
Страница 936: ...EC Declarations of Conformity Appendix A 36 ...
Страница 937: ...Appendix EC Declarations of Conformity FR F800 A 37 ...
Страница 938: ...EC Declarations of Conformity Appendix A 38 ...
Страница 939: ......