328
13. (T) Multi-Function Input Terminal Parameters
13.6 Input terminal function selection
13.6
Input terminal function selection
Use the following parameters to select or change the input terminal functions.
*1
The initial value is for standard models.
*2
The initial value is for the Ethernet model and the safety communication model.
*3
The setting range differs depending on the model. For more information, refer to the parameters available for each signal.
Input terminal function assignment
• Signals can be input to the inverter by using physical terminals (except for the FR-E800-SCE) or via communication.
• Use the following parameters to assign functions to input terminals. Check the terminal available for each parameter.
○
: Assignment/input available,
─
: Assignment/input unavailable (no function)
Pr.
Name
Initial
value
Initial signal
Setting range
178
T700
STF/DI0 terminal
function selection
60
STF (Forward rotation command)
0 to 5, 7, 8, 10, 12 to 16, 18, 23 to 27, 30, 37, 42,
43, 46, 47, 50, 51, 60, 62, 65 to 67, 72, 74, 92,
9999
179
T701
STR/DI1 terminal
function selection
61
STR (Reverse rotation command)
0 to 5, 7, 8, 10, 12 to 16, 18, 23 to 27, 30, 37, 42,
43, 46, 47, 50, 51, 61, 62, 65 to 67, 72, 74, 92,
9999
180
T702
RL terminal function
selection
0
RL (Low-speed operation command)
0 to 5, 7, 8, 10, 12 to 16, 18, 23 to 27, 30, 37, 42,
43, 46, 47, 50, 51, 62, 65 to 67, 72, 74, 92,
9999
181
T703
RM terminal function
selection
1
RM (Middle-speed operation command)
182
T704
RH terminal function
selection
2
RH (High-speed operation command)
183
T709
MRS terminal
function selection
24
MRS (Output stop)
184
T711
RES terminal
function selection
RES (Inverter reset)
9999
No function
185
T751
NET X1 input
selection
9999
No function
0 to 4, 8, 13 to 15, 18, 23, 24, 26, 27, 30, 37, 42,
43, 46, 47, 50, 51, 72, 74, 92, 9999
186
T752
NET X2 input
selection
9999
No function
187
T753
NET X3 input
selection
9999
No function
188
T754
NET X4 input
selection
9999
No function
189
T755
NET X5 input
selection
9999
No function
Pr.
Name
Initial
value
Setting range
Description
699
T740
Input terminal filter
9999
5 to 50 ms
Set the time delay for the input terminal response.
9999
No filter for the input terminal
Pr.
Terminal
name
External input terminal (physical terminal)
Input via
communication
FR-E800
FR-E800-E
FR-E800-SCE
178
STF/DI0
○
(STF)
○
(DI0)
—
Forward rotation
command only
179
STR/DI1
○
(STR)
○
(DI1)
—
Reverse rotation
command only
180
RL
○
—
—
○
181
RM
○
—
—
○
182
RH
○
—
—
○
183
MRS
○
—
—
○
184
RES
○
—
—
○
185
NET X1
—
—
—
○
186
NET X2
—
—
—
○
187
NET X3
—
—
—
○
188
NET X4
—
—
—
○
189
NET X5
—
—
—
○
Содержание FR-E800
Страница 17: ...16 1 Introduction 1 3 Related manuals MEMO ...
Страница 51: ...50 2 Basic Operation 2 8 I O terminal function assignment MEMO ...
Страница 89: ...88 3 Parameters 3 4 Parameter list by function group number MEMO ...
Страница 135: ...134 5 Speed Control 5 9 Troubleshooting in the speed control MEMO ...
Страница 153: ...152 6 Torque Control 6 7 Troubleshooting in torque control MEMO ...
Страница 195: ...194 8 E Environment Setting Parameters 8 18 Current average value monitor signal MEMO ...
Страница 237: ...236 10 D Operation Command and Frequency Command 10 6 Operation by multi speed setting MEMO ...
Страница 339: ...338 13 T Multi Function Input Terminal Parameters 13 9 Start signal operation selection MEMO ...
Страница 455: ...454 16 G Control Parameters 16 13 Speed smoothing control MEMO ...
Страница 481: ...480 18 Appendix 18 4 Parameters functions and instruction codes under different control methods MEMO ...