124
5. Speed Control
5.6 Speed feed forward control, model adaptive speed control
5.6
Speed feed forward control, model adaptive speed
control
• Speed feed forward control or model adaptive speed control can be selected using parameter settings.
Under speed feed forward control, the motor trackability for speed command changes can be improved.
Under model adaptive speed control, the speed trackability and the response level to motor external disturbance torque
can be adjusted individually.
Speed feed forward control (Pr.877 = "1")
• When the load inertia ratio is set in
Pr.880
, the required torque for the set inertia is calculated according to the acceleration
and deceleration commands, and the torque is generated quickly.
• When the speed feed forward gain is 100%, the calculation result for speed feed forward is applied as is.
• If the speed command changes suddenly, the torque is increased by the speed feed forward calculation. The maximum
limit for the speed feed forward torque is set in
Pr.879
.
• The speed feed forward result can also be lessened with a primary delay filter in
Pr.878
.
NOTE
• The speed feed forward control is enabled for the first motor.
• Even if the driven motor is switched to the second motor while
Pr.877
= "1", the second motor is operated as
Pr.877
= "0".
Model adaptive speed control (Pr.877 = "2", Pr.828)
• The model speed of the motor is calculated, and the feedback is applied to the speed controller on the model side. Also,
this model speed is set as the command of the actual speed controller.
Sensorless
Sensorless
Sensorless Vector
Vector
Vector
Pr.
Name
Initial
value
Setting
range
Description
828
G224
Model speed control gain
100 rad/s
0 to 1000 rad/
s
Set the gain for the model speed controller.
877
G220
Speed feed forward
control/model adaptive
speed control selection
0
0
Perform normal speed control.
1
Perform speed feed forward control.
2
Model adaptive speed control becomes valid.
878
G221
Speed feed forward filter
0.01 s
0.01 to 1 s
Set the primary delay filter for the result of the speed feed forward
calculated from the speed command and load inertia ratio.
879
G222
Speed feed forward torque
limit
150%
0% to 400%
Set a maximum limit for the speed feed forward torque.
880
C114
Load inertia ratio
7 times
0 to 200 times Set the load inertia ratio for the motor.
881
G223
Speed feed forward gain
0%
0% to 1000% Set the calculation result for speed feed forward as the gain.
Load inertia ratio
J s
[Pr. 880]
[Pr. 878]
Speed feed
forward
filter
[Pr. 879]
Speed feed
forward torque
limit
Speed feed
forward
gain
[Pr. 881]
Speed feed forward control
Torque control
Speed estimator
Speed
control
P gain 1
[Pr. 820]
Speed control
integral time 1
[Pr. 821]
M
Actual speed controller
+
-
+
+
+
Speed command
[Block diagram]
.
Содержание FR-E800
Страница 17: ...16 1 Introduction 1 3 Related manuals MEMO ...
Страница 51: ...50 2 Basic Operation 2 8 I O terminal function assignment MEMO ...
Страница 89: ...88 3 Parameters 3 4 Parameter list by function group number MEMO ...
Страница 135: ...134 5 Speed Control 5 9 Troubleshooting in the speed control MEMO ...
Страница 153: ...152 6 Torque Control 6 7 Troubleshooting in torque control MEMO ...
Страница 195: ...194 8 E Environment Setting Parameters 8 18 Current average value monitor signal MEMO ...
Страница 237: ...236 10 D Operation Command and Frequency Command 10 6 Operation by multi speed setting MEMO ...
Страница 339: ...338 13 T Multi Function Input Terminal Parameters 13 9 Start signal operation selection MEMO ...
Страница 455: ...454 16 G Control Parameters 16 13 Speed smoothing control MEMO ...
Страница 481: ...480 18 Appendix 18 4 Parameters functions and instruction codes under different control methods MEMO ...