Parameter
Useful functions
FR-E700 SC EC/ENE
6 - 317
6.21 Useful
functions
6.21.1
Cooling fan operation selection (Pr. 244)
You can control the operation of the cooling fan (FR-E720S-050SC or more, FR-E740-040SC or more)
built in the inverter.
The above parameter can be set when Pr. 160 "User group read selection" = 0.
In either of the following cases, fan operation is regarded as faulty, "FN" is shown on the operation
panel, and the fan fault "FAN" and alarm "LF" signals are output.
Pr. 244 = "0"
When the fan comes to a stop with power on.
Pr. 244 = "1"
When the fan stops during the fan ON command while the inverter is running.
For the terminal used for FAN signal output, set "25" (source logic) or "125" (sink logic) to any of Pr. 190
to Pr. 192 "Output terminal function selection", and for the LF signal, set "98" (source logic) or "198"
(sink logic).
Purpose
Parameters that must be set
Refer to
Section
To determine the maintenance time of
parts.
Cooling fan operation selection
Pr. 244
Inverter part life display
Pr. 255–Pr. 259
Maintenance output function
Pr. 503–Pr. 504
Freely available parameter
Current average value monitor signal
Pr. 555–Pr. 557
Increase cooling fan life
Free parameter
Pr. 888–Pr. 889
Pr. No.
Name
Initial Value
Setting
Range
Description
Parameters referred to
Refer to
Section
244
Cooling fan operation
selection
1
0
Operates at power on
Cooling fan on/off control invalid (The cooling fan
is always on at power on)
190–192 Output terminal
function selection
1
Cooling fan on/off control valid
The fan is always on while the inverter is running.
During a stop, the inverter status is monitored
and the fan switches on-off according to the
temperature of the heatsink.
NOTE
When terminal assignment is changed using Pr. 190 to Pr. 192 "Output terminal function selec-
tion", the other functions may be affected. Please make setting after confirming the function of
each terminal.
Содержание fr-e700 series
Страница 2: ......
Страница 4: ......
Страница 20: ...Contents XVI ...
Страница 112: ...Operation panel Operation 4 20 ...
Страница 154: ...External operation Basic settings 5 42 ...
Страница 528: ...CC Link IE Field Network Basic Parameter 6 374 ...
Страница 562: ...Meters and measuring methods Troubleshooting 7 34 ...
Страница 606: ...A 30 Index Appendix ...
Страница 607: ......