Parameter
Communication operation and setting
FR-E700 SC EC/ENE
6 - 253
●
Response time
Formula for data sending time:
햲
The communication specifications are listed in the table below:
The data check time related to different functions is shown in the table below:
I001327E
Fig. 6-128:
Response time
Data
sending time [s]
=
1
´
Number of data
characters
(refer to page 6-247)
´
Communications specifications
(total number of bits)
햲
Communication
speed
(Baudrate)
Name
Number of Bits
Stop bit length
1 bit
2 bits
Data length
7 bit
8 bits
Parity check
Yes
1 bit
No
0 bits
Tab. 6-76:
Communication specifications
NOTES
In addition to the above, 1 start bit is necessary.
Minimum number of total bits: 9 bits. Maximum number of total bits: 12 bits.
Function
Data Check Time
Various monitors, run command, frequency setting (RAM)
< 12 ms
Parameter read/write, frequency setting (E²PROM)
< 30 ms
Parameter clear/all clear
< 5 s
Reset command
— (no answer)
Tab. 6-77:
Data check time
Computer
Data flow
Inverter
Inverter
Data flow
Computer
Data sending time (Refer to the following formula)
Inverter data processing time = Waiting time
+
Data check time
(setting 10ms)
(Depends on the instruction code
(refer to Tab. 6-77))
Time
Data sending time (Refer to the following formula)
10ms or more necessary
Содержание fr-e700 series
Страница 2: ......
Страница 4: ......
Страница 20: ...Contents XVI ...
Страница 112: ...Operation panel Operation 4 20 ...
Страница 154: ...External operation Basic settings 5 42 ...
Страница 528: ...CC Link IE Field Network Basic Parameter 6 374 ...
Страница 562: ...Meters and measuring methods Troubleshooting 7 34 ...
Страница 606: ...A 30 Index Appendix ...
Страница 607: ......