Basic settings
Simple mode parameter list
FR-D700 SC EC
5 - 5
5.1.3
Increase the starting torque (Pr. 0)
Set this parameter when the motor with a load does not rotate, an alarm OL is output, resulting
in an inverter trip due to OC1, etc.
Pr.
No.
Name
Initial Value
Setting
Range
Description
0
Torque boost
FR-D720S-008SC to
042SC
FR-D740-012SC and
022SC
6%
0–30%
Motor torque in the low-frequency range can be
adjusted to the load to increase the starting motor
torque.
FR-D720S-070SC and
100SC
FR-D740-036SC to
080SC
4%
FR-D740-120SC and
160SC
3%
Example
쑴
When the motor with a load does not rotate, increase the Pr. 0 value 1% by 1% unit by look-
ing at the motor movement. The guideline is for about 10% change at the greatest.
Fig. 5-3:
Relation between output frequency and output
voltage
I001098E
V/F
V/F
V/F
Setting
range
Pr. 0, Pr. 46
Output v
o
ltage
Base
frequency
Output frequency [Hz]