4.2 Terminals
Option FR-A8AX terminal
Inverter terminal
Refer to the Instruction Manual (Detailed) for details of
Pr.178 to Pr.189 (input terminal function selection)
and
Pr.190 to Pr.196
(output terminal function selection)
.
Terminal
Symbol
Terminal Name
Description
X0 to X15
Digital signal input terminal
Input the digital signal at the relay contact or open collector terminal.
Using
Pr. 360
, speed or position command is selected as the command signal entered.
DY
Data read timing input signal
terminal
Used when a digital signal read timing signal is necessary. Data is read only during the DY
signal is on.
By switching the DY signal off, the X0 to X15 data before signal-off is retained.
Terminal
(Signal)
Terminal (Signal) Name
Application Explanation
Input
X22
Orientation command
Used to enter an orientation signal for orientation.
For the terminal used for X22 signal input, set "22" in any of
Pr. 178 to Pr. 189
to assign
the function.
Output
ORA
Orientation complete
Switched LOW if the orientation has stopped within the in-position zone while the start
and X22 signals are input.
For the terminal used for the ORA signal output, assign the function by setting "27
(positive logic) or 127 (negative logic)" in any of
Pr. 190 to Pr. 196
.
ORM
Orientation fault
Switched LOW if the orientation has not completed within the in-position zone while the
start and X22 signals are input.
For the terminal used for the ORA signal output, assign the function by setting "28
(positive logic) or 128 (negative logic)" in any of
Pr. 190 to Pr. 196
.