Parameters
(N) Operation via communication and its settings
FR-A800
5 - 677
Ethernet function selection (Pr. 1427 to Pr. 1429)
Refer to the Instruction Manual of the device connected via Ethernet, and set Pr. 1427 to Pr. 1429
(Ethernet function selection 1 to 3) according to the application and protocol.
A communication socket is provided only for the selected application.
If both application and protocol settings are identical in Pr. 1427 to Pr. 1429, the priority of the
setting is defined as follows: Pr. 1427 > Pr. 1428 > Pr. 1429.
Example:
When Pr. 1427 = "5001", Pr. 1428 = "5006", Pr. 1429 = "5013", "5001" and "5013" are valid.
To connect the inverter and FR Configurator2 via the MELSOFT / FA product for Ethernet commu-
nication, set "5001 (initial value)" or "5002" according to the protocol type (UDP/IP or TCP/IP) in
any of Pr. 1427 to Pr. 1429.
When the inverter is connected with other equipment via a hub, and if the communication
between the other equipment and the hub is interrupted and resumed, the communication
between the inverter and the other equipment may not be established depending on the speci-
fications of the hub. To re-establish communication with the other equipment, reset the inverter
to forcefully close the connection. (Setting a shorter time in Pr. 1455 "Keepalive time" is also
effective as a preventive measure (refer to page 5-679)).
For details, refer to the Instruction Manual of FR Configurator2.
Pr. 1427 to Pr. 1429 setting
Application
Number of
connectable clients
Refer to
page
502
Modbus®/TCP
TCP/IP
3
5000
MELSOFT / FA product
connection
UDP/IP
No limit
5001 (Pr. 1427 initial value)
5002
TCP/IP
5006
UDP/IP
No limit
5007
TCP/IP
5008
UDP/IP
No limit
5010
SLMP
UDP/IP
No limit
5011
5012
TCP/IP
5013
45237 (Pr. 1428 setting)
iQSS
UDP/IP
No limit
61450
CC-Link IE Field Network Basic
UDP/IP
No limit
9999 (Pr. 1429 initial value)
Unselected
—
Tab. 5-309:
Ethernet function selection settings
Содержание FR-A820-00046 (0.4K)
Страница 2: ......
Страница 4: ......
Страница 144: ...System configuration for Ethernet communication FR A800 E Installation and wiring 2 114 ...
Страница 202: ...Basic operation procedure JOG operation Basic operation 4 32 ...
Страница 1090: ...Check first when you have a trouble Protective functions 6 50 ...
Страница 1110: ...Measurement of main circuit voltages currents and powers Precautions for maintenance and inspection 7 20 ...
Страница 1188: ...EC Declarations of Conformity Appendix A 48 A 7 EC Declarations of Conformity A 7 1 FR A820 FR A840 FR A842 series ...
Страница 1189: ...Appendix EC Declarations of Conformity FR A800 A 49 ...
Страница 1190: ...EC Declarations of Conformity Appendix A 50 ...
Страница 1191: ...Appendix EC Declarations of Conformity FR A800 A 51 ...
Страница 1192: ...EC Declarations of Conformity Appendix A 52 ...
Страница 1193: ...Appendix EC Declarations of Conformity FR A800 A 53 ...
Страница 1194: ...EC Declarations of Conformity Appendix A 54 ...
Страница 1195: ...Appendix EC Declarations of Conformity FR A800 A 55 ...
Страница 1196: ...EC Declarations of Conformity Appendix A 56 ...
Страница 1197: ...Appendix EC Declarations of Conformity FR A800 A 57 ...
Страница 1198: ...EC Declarations of Conformity Appendix A 58 ...
Страница 1199: ...Appendix EC Declarations of Conformity FR A800 A 59 ...
Страница 1200: ...EC Declarations of Conformity Appendix A 60 ...
Страница 1201: ...Appendix EC Declarations of Conformity FR A800 A 61 ...
Страница 1202: ...EC Declarations of Conformity Appendix A 62 ...
Страница 1203: ...Appendix EC Declarations of Conformity FR A800 A 63 ...
Страница 1204: ...EC Declarations of Conformity Appendix A 64 ...
Страница 1205: ...Appendix EC Declarations of Conformity FR A800 A 65 ...
Страница 1206: ...EC Declarations of Conformity Appendix A 66 ...
Страница 1207: ...Appendix EC Declarations of Conformity FR A800 A 67 ...
Страница 1208: ...EC Declarations of Conformity Appendix A 68 ...
Страница 1209: ...Appendix EC Declarations of Conformity FR A800 A 69 ...
Страница 1210: ...EC Declarations of Conformity Appendix A 70 ...
Страница 1211: ...Appendix EC Declarations of Conformity FR A800 A 71 ...
Страница 1212: ...EC Declarations of Conformity Appendix A 72 A 7 2 FR A846 series ...
Страница 1213: ...Appendix EC Declarations of Conformity FR A800 A 73 ...
Страница 1214: ...EC Declarations of Conformity Appendix A 74 ...
Страница 1215: ...Appendix EC Declarations of Conformity FR A800 A 75 ...
Страница 1216: ...EC Declarations of Conformity Appendix A 76 A 7 3 Frequency inverters with option unit FR A8NP ...
Страница 1217: ......