69
OBJECT MAP
*1
After reset with 01 set, this value must be set to 00 before inverter reset may be performed.
*2
This data is only updated after inverter reset or power-on reset.
*3
When this ID is set, it is reflected to bit7 to 11 of
Pr. 346
and Class 0x05 Instance 2 Attribute 7, 13, 14 .
*4
When this ID is set, it is reflected to bit2 to 6 of
Pr. 346
and Class 0x05 Instance 2 Attribute 8, 15, 16 .
(2) Service
9
Get
Ready
1
0
During reset or alarm occurrence
1
Stop or running
10
Get
Faulted
0
0
No fault present
1
Fault occurred (latched)
12
Get/Set FaultRst
(fault reset)
0
0
Reset release at fault occurrence
1
Reset execution at fault occurrence
15
Get
CtrlFromNet
(operation command
1
0
Other than DeviceNet communication
operation
1
DeviceNet communication operation
140
Get/Set Instance ID of Input
Assembly
0x47
(71)
0x46
Input Instance 70
0x47
Input Instance 71
0xB0
Input Instance 176
141
Get/Set Instance ID of Output
Assembly
0x15
(21)
0x14
Output Instance 20
0x15
Output Instance 21
0x7E
Output Instance 126
Service Code
Description
0x0E
Get Attribute Single
0x10
Set Attribute Single
Class 0x29 Instance 1
Attribute ID Access
Name
Initial
Value
Range
Description