49
OBJECT MAP
7.1.2 Class 0x01 Instance 1
(1) Attribute
*1
High byte of hexadecimal word data means integer and low byte means decimal.
For example, when the read data is 0x010A, it means version 1.010.
*2
Bit definition
Bit0: 0 = allocated, 1 = not allocated, Bit2: 0, Bit8: 1 = minor fault occurrence, Bit9: 0, Bit10: 1 = LED is flickering
red, Bit11: 1 = LED is lit red
*3
As the actual data, 0x04, 0x45, 0x37, 0x30, and 0x30 are stored. 0x04 means 4 byte data and the rest means
ASCII code of "E700".
(2) Service
*1
As set in
Pr. 75
. Refer to
the Instruction Manual of the inverter
for details of
Pr. 75
.
*2
If the inverter does not accept the command, neither inverter reset nor all parameter clear will be performed.
Attribute ID
Access
Description
Data
Length
Attribute Value
1
Get
Vendor ID (Mitsubishi electric)
Word
161
2
Get
Device Type (AC drive)
Word
02
3
Get
Product Code
Word
49
4
Get
Revision
Struct
1.YYY
5
Get
Status
Word
6
Get
Serial Number
Double
Word
xxxxxxxx
7
Get
Product Name (FR-E700)
5 Byte
E700
Service Code
Symbol
Name
Setting Range
Description
0x05
Reset
Reset
0
Inverter reset
*2
1
Inverter reset after all parameter
clear
*2
0x0E
Get
Get_Attribute_Single
⎯
Get Attribute Single