INSTALLATION
CAUTION
•
Only one type of option per inverter may be used. When two or more options are mounted, priority is in the
order of inverter option connectors 1, 2 and 3. The options having lower priority are inoperative.
•
When the inverter cannot recognize that the option is mounted due to improper
installation, etc., "
to
" (option fault) are displayed. The errors
shown differ according to the mounting positions (connectors 1, 2, 3).
•
When mounting/removing an option, hold the sides of the option. Do not press
on the parts on the option circuit board. Stress applied to the parts by pressing, etc. may cause a failure.
•
Take caution not to drop a hex-head screw for option mounting or mounting screw during mounting and
removal.
•
Pull the option straight out when removing. Pressure applied to the connector and to the option circuit
board may break the option.
Mounting
Position
Error
Display
Connector 1
Connector 2
Connector 3
Содержание FR-A7AP